Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Geriatrics ; (12): 780-784, 2022.
Article in Chinese | WPRIM | ID: wpr-957296

ABSTRACT

Objective:To investigate the clinical effect of Infix combined with hollow screws for the treatment of pelvic injuries with pubic symphysis separation in middle-aged and elderly patients.Methods:Data of 8 middle-aged and elderly patients with pelvic injuries due to pubic symphysis separation undergone treatment from January 2017 to December 2020 were retrospectively analyzed.Results:The average operating time of 8 patients was (46.0±6.2)min(range: 40-62min); the average intraoperative blood loss was (32.0±5.6)ml(range: 25-50 ml); the average length of incisions at the iliac screw was(2.6±0.4)cm(range: 2.0-3.5 cm); the average length of incisions at the hollow screw was (1.1±0.3)cm(range: 0.8-1.5 cm); and the average times of fluoroscopy were (36.0±6.0)times(range: 28-52 times). Postoperative X-ray and CT examinations showed that the reduction of the pubic symphysis was good, the inserted iliac screws and cannulated screws were positioned accurately, and the incision healed well.Based on Matta's criteria, postoperative radiological outcomes were evaluated, with 7 cases rated as excellent and 1 as good, giving an excellent to good rate of 100%(8/8). The average followed up time for all 8 patients was (15.0±4.2)months(range: 6-24 months). Pelvic X-ray and CT examinations at the last follow-up showed that the fractures healed well and the pubic symphysis reduction did not fail.Infix and cannulated screws in the pubic symphysis were removed 10-12 weeks after surgery[average: (10.5±0.5)weeks]. According to the Majeed Pelvic Score, 5 cases were rated as excellent, 2 cases as good and 1 as fair, with an excellent to good rate of 87.5%(7/8). One patient had symptoms related to the lateral femoral cutaneous nerve that disappeared after 3 months.One patient developed deep venous thrombosis after surgery, and the filter was placed and removed 10 weeks later.Conclusions:Using Infix plus cannulated screws for the treatment of pelvic injuries in middle-aged and elderly patients with pubic symphysis separation has the advantages of limited trauma and intraoperative blood loss, good fixation and few complications.

2.
Chinese Journal of Tissue Engineering Research ; (53): 4957-4961, 2014.
Article in Chinese | WPRIM | ID: wpr-453217

ABSTRACT

BACKGROUND:There is no unified method for treatment of intertrochanteric fracture. Previous dynamic hip screw fixation has some shortcomings, and is gradual y replaced by intramedul ary nail fixation. interTan is a compression interlocking intramedul ary nail designed by Smith Nephew in USA according the characteristics of intertrochanteric fracture. Unique design of pressurized screw thread has control able linear pressure. Moreover, it has the stability of Z-effect anti-rotation. OBJECTIVE:To analyze the clinical therapeutic effects and superiority of interTan compression interlocking intramedul ary nail for intertrochanteric fracture. METHODS:A total of 60 patients with intertrochanteric fracture undergoing interTan compression interlocking intramedul ary nail in the Department of Orthopedics, Beijing Chaoyang Emergency Rescue Center from January 2011 to December 2012 were enrol ed in the experimental group. A total of 60 patients with intertrochanteric fractures receiving dynamic hip screw fixation in the Department of Orthopedics, Beijing Chaoyang Emergency Rescue Center from January 2009 to December 2010 were enrol ed in the control group. RESULTS AND CONCLUSION:Peri-operative bleeding volume, postoperative ambulation time, numerical rating scale score, radiographic healing time and weight-bearing time in the experimental group were lower than those of control group. At 3, 6 months and 1 year after fixation, Harris score and hospital for special surgery knee score were higher in the experimental group than in the control group. These data indicated that compared with dynamic hip screw, interTan compression interlocking intramedul ary nail has unique stability due to its design. Internal fixation can reduce operation trauma, promote fracture healing and improve joint function, and exhibit good clinical therapeutic effects for intertrochanteric fractures.

SELECTION OF CITATIONS
SEARCH DETAIL