Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
China Occupational Medicine ; (6): 431-436, 2021.
Article in Chinese | WPRIM | ID: wpr-923213

ABSTRACT

OBJECTIVE: To evaluate the suitability of two pretreatment methods, the nitric acid digestion method and the elution method, and two measurement modes of inductively coupled plasma-mass spectrometry(ICP-MS), the No gas mode and the helium collision(He) mode, for the determination of lithium and its compounds in the workplace air. METHODS: We collected lithium and its compounds in the air of the workplace using the microporous filter membrane, and two pretreatment methods, the nitric acid digestion and elution methods were used for processing, and measured with the No gas mode and the He mode of ICP-MS. RESULTS: The good linearity range of lithium concentration in No gas mode and He mode of ICP-MS method was 0.00-500.00 μg/L, and the correlation coefficient was 0.999. The detection limit and the lower limit of quantification of lithium were 0.04 and 0.13 μg/L respectively in the No gas mode. In He gas mode: they were 0.12 and 0.39 μg/L respectively. Using the nitric acid digestion method for pre-treatment, the recovery rate of lithium addition was 96.9%-104.9%; the within-run and the between-run relative standard deviations were 3.3%-5.0% and 2.9%-5.3% respectively. Using the elution method for pre-treatment, the recovery rate of lithium addition was 97.6%-102.1%; the within-run and the between-run relative standard deviation were 3.3%-4.6% and 3.4%-4.8%, respectively. The sample could be stored at room temperature for at least 14 days. CONCLUSION: The ICP-MS method can be used as a new technology for detecting lithium and its compounds in the air of workplace. It is recommended that the elution method and the No gas mode be the first choice when measuring lithium and its compounds.

2.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 204-210, 2019.
Article in Chinese | WPRIM | ID: wpr-817724

ABSTRACT

@#【Objective】To evaluate the effects of methanol extract of Panax Notoginseng flower(PNFM)on platelet function in healthy human.【Methods】Platelet rich plasma were separated from venous blood of healthy volunteers and incubated with different concentrations(0,100,300 and 500 μg/mL)of PNFM for 20 min. After using ADP as agonist, granule-secretion were tested by CD62P expression and ATP release;integrin-αIIbβ3 activation was examined by PAC-1; Test platelet aggregation by turbidimetry ;Immunofluorescence examine platelet spreading on fibrinogen ;Changes in cytoplasmic calcium was studied using Fluo 3-AM,calcium ionophore. 【Results】After using ADP as agonist ,PNFM significantly inhibited platelet aggregation,compared to the control group(72.00±6.08),the 500μg/mL group decreased to 35.67±3.78(P<0.01);Compared to the control group(30.05±6.48),PNFM reduced the CD62P expression on platelet surface,the 500 μg/mL group decreased to 2.66±0.90(P<0.001);PNFM inhibited the expression of PAC-1 as a marker of the integrin- αIIbβ3 comformation,compared to the control group(33.37 ± 8.12),the 500 μg/mL group decreased to 11.89±6.12(P<0.01);Compared to the control group(1.93±0.47),all dose groups attenuated platelet ATP release,the 500 μg/mL group decreased to 35.67±3.78(P<0.01);Results demonstrated that 500 μg/mL PNFM markedly decreases the surface area of the spreading platelets(89.57±17.34 to 25.12±3.52,P<0.001),and all doses were affected;The Ca2 + mobilization was also reduced by all PNFM doses,compared to the control group(183.87 ± 11.59),the 500 μg/mL group was decreased to 71.25±5.33(P<0.001).【Conclusions】PNFM attenuated platelet activation,spreading,and aggregation; Our results provided new ideas for prevention and treatment of cardiovascular and cerebrovascular diseases.

3.
China Occupational Medicine ; (6): 345-349, 2016.
Article in Chinese | WPRIM | ID: wpr-876958

ABSTRACT

OBJECTIVE: To establish a methodology for determining indium in human whole blood,serum and urine by inductively coupled plasma-mass spectrometry( ICP-MS). METHODS: The whole blood,serum and urine samples were diluted 10 times in 0. 01%( mass fraction) Triton X-100 plus 0. 50%( mass fraction) nitric acid solution,and the indium level was determined by ICP-MS. Rhodium standard solution was used as the internal standard control. RESULTS: The working curve obtained from measurement of whole blood,serum and urine of normal individuals was compared to the standard curve and showed no significant difference in quantitative analysis( P > 0. 05). The linearity range of indium concentration in whole blood,serum and urine was 0. 000-20. 000 μg / L,and all the correlation coefficients were greater than 0. 999 with a detection limit of 0. 144 μg / L. The recovery rates of whole blood,serum and urine were 87. 90%-95. 92%,91. 50%-94. 20% and 90. 40%-96. 57%,respectively. The relative standard deviations( RSDs) of within-run precision were 3. 81%-7. 05%,3. 75%-5. 90% and 4. 31%-6. 62%,respectively. The RSDs of between-run precision were 2. 90%-7. 10%,3. 80%-5. 92% and 4. 16%-5. 94%,respectively. Samples could be stored for at least 14 days under the temperature of- 20 ℃. The indium in whole blood,serum and urine of workers occupationally exposed to indium( exposure group,135 person-time) and control group workers( 120 person-time) were examined. Indium was detected for 17 person-time in whole blood and serum in the exposure group with a detection rate of 1. 26%. Indium was not detected in urine samples in exposure group. It was not detected in all samples in control group. CONCLUSION: This methodology has features of simple operation,high accuracy and good precision,which is suitable for the accurate quantitative analysis of indium in biological samples.

4.
Journal of Zhejiang University. Medical sciences ; (6): 388-396, 2014.
Article in Chinese | WPRIM | ID: wpr-251690

ABSTRACT

<p><b>OBJECTIVE</b>To screen out effective lung cancer associated antigens for early diagnosis in order to improve the level of early diagnosis.</p><p><b>METHODS</b>A T7 phage display cDNA library of human early lung cancer was developed. And then differential phage clones were picked out to be sequenced and bioinformatically analyzed. With the 8 screened differential phage clones a lung cancer associated antigen microarray was established to evaluate the single or combined roles of all the selected antigens in the diagnosis of lung cancer by the reaction of the antigens plus serum from normal subjects and patients with lung cancer, respectively.</p><p><b>RESULTS</b>The titer of the constructed cDNA library was 3.71×10 (6); pfu/ml and the number of phage was 1.11×10 (6); pfu, with a recombination rate of cDNA library over 90%. Nine differential phage clones were initially screened out, but the genes of two antigens (A42 and A83) were found the same. Bioinformatics analyses showed that the genes of the 8 antigens were known before and they were all proven to be related with tumor except A64. The positive reaction rates of the 8 antigens with serum from lung cancer patients were significantly higher than that with serum from normal subjects (Ps<0.05). When keeping specificity no less than 60%, the sensitivity of each antigen in predicting lung cancer alone was under 70% and the areas under curve (AUC) of the antigens were all under 0.8. However, when all the antigens were combined to detect lung cancer, the sensitivity and specificity was 90.8% and 94.1%, respectively, and AUC reached up to 0.969.</p><p><b>CONCLUSION</b>A T7 phage display cDNA library with a good quality of capacity, recombination rate and representativeness of human early lung cancer was successfully developed, and 8 lung cancer associated antigens were screened out. A combination of the 8 antigens can greatly improve their value to diagnose lung cancer with a higher sensitivity and specificity (both above 90%).</p>


Subject(s)
Humans , Antigens, Neoplasm , Genetics , Early Detection of Cancer , Methods , Gene Library , Lung Neoplasms , Diagnosis , Genetics , Sensitivity and Specificity
5.
Biomedical and Environmental Sciences ; (12): 268-280, 2014.
Article in English | WPRIM | ID: wpr-270605

ABSTRACT

<p><b>OBJECTIVE</b>To investigate the relationship between atopic allergy and depression and the role of DBP in the development of depression.</p><p><b>METHODS</b>BALB/c mice were randomly divided into eight groups: saline; ovalbumin (OVA)-immunized; saline+DBP (0.45 mg/kg•d); saline+DBP (45 mg/kg•d); DBP (0.45 mg/kg•d) OVA-immunized; DBP (45 mg/kg•d) OVA-immunized; saline+hydrocortisone (30 mg/kg•d); and hydrocortisone (30 mg/kg•d)-exposed OVA-immunized. Behavior (e.g. open-field, tail suspension, and forced swimming tests), viscera coefficients (brain and spleen), oxidative damage [e.g. reactive oxygen species (ROS), malondialdehyde (MDA), and glutathione (GSH)], as well as levels of IgE and IL-4, were then analyzed.</p><p><b>RESULTS</b>In the saline and OVA groups, the degree of depression symptoms in mice increased with increasing DBP concentration. Additionally, the OVA-immunity groups were associated with more serious depressive behavior compared with the same exposure concentration in the saline group. Oxidative damage was associated with a dose-dependent increase in DBP in the different groups. IL-4 and IgE levels were associated with low-dose DBP stimulation, which changed to high-dose inhibition with increasing DBP exposure, possibly due to spleen injury seen at high DBP concentrations.</p><p><b>CONCLUSION</b>Development of an atopic allergy has the potential to increase the risk of depression in mice, and it seems that DBP helps OVA to exert its effect in our present model. Moreover, the results of our study implicate a certain connection between brain oxidative stress and depression, which deserves a further exploration.</p>


Subject(s)
Animals , Male , Mice , Behavior, Animal , Body Weight , Depression , Blood , Allergy and Immunology , Dibutyl Phthalate , Allergy and Immunology , Toxicity , Environmental Pollutants , Allergy and Immunology , Toxicity , Hydrocortisone , Hypersensitivity, Immediate , Blood , Immunization , Immunoglobulin E , Blood , Interleukin-4 , Blood , Mice, Inbred BALB C , Ovalbumin , Oxidative Stress
SELECTION OF CITATIONS
SEARCH DETAIL