1.
Journal of Forensic Medicine ; (6): 285-287, 2006.
Article in Chinese | WPRIM | ID: wpr-983201

ABSTRACT

OBJECTIVE@#To separate and determine scopolamine from the food in a poisoning case by GC/MS.@*METHODS@#The scopolamine was determined by GC/MS/El used CP5860(CP-sil8CB) column (30 mx 0.25 mmx 0.33 microm) with liquid- liquid extraction.@*RESULTS@#The deny scopolamine was found in the case sample, and the chromatographic separation of the peaks is fine.@*CONCLUSION@#The method is accurate and reliable.


Subject(s)
Humans , Male , Foodborne Diseases/etiology , Forensic Medicine/methods , Gas Chromatography-Mass Spectrometry/methods , Hallucinations/diagnosis , Psychoses, Substance-Induced/etiology , Scopolamine/poisoning , Sensitivity and Specificity , Solanaceae/chemistry , Solvents/chemistry