Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Journal of Practical Radiology ; (12): 200-202, 2018.
Article in Chinese | WPRIM | ID: wpr-696782

ABSTRACT

Objective To measure the parameters of bronchus and peripheral pulmonary small vessel in the early simple pulmonary contusion, and to explore the changes of bronchial and pulmonary small blood vessels after pulmonary contusion.Methods The chest CT images of 30 patients with early simple pulmonary contusion were collected retrospectively,images were then automatically segmented using FACT-Digital lung TM software.Ipsilateral,contralateral bronchial parameters (luminal cross-sectional area,wall thickness,internal and external diameter,inner and outer circumference and luminal density)and pulmonary small vessel parameters (number of vessels in the visual area,total blood vessel area)for 33 pulmonary contusion cases were measured respectively,finally,correlation between lung contusion area and bronchial and small vessel parameters were analyzed.Results Ipsilateral bronchial parameters (luminal cross-sectional area, wall thickness,internal and external diameter,inner and outer circumference and luminal density)and pulmonary small vessel parameters (number of vessels in the visual area,total blood vessel area)were greater than those in the contralateral(P<0.05).The area of pulmonary contusion was not associated with bronchial parameters nor pulmonary small vessel parameters.Conclusion Quantitative CT analysis can intuitively show the changes of bronchial and pulmonary small blood vessels in patients with early simple pulmonary contusion.

2.
Chinese Medical Equipment Journal ; (6): 123-126, 2017.
Article in Chinese | WPRIM | ID: wpr-608120

ABSTRACT

The limitations of the traditional radio frequency wireless communications technology were introduced.Visible light communication technology had its advantages,key technologies,technical standards and application prospect in medical field described in detail,which eliminated the needs for radio carrier and the interferences between the wireless communication instruments and medical electronic devices,and thus was an ideal choice for wireless network communication in medical field.

3.
Chinese Journal of Tissue Engineering Research ; (53): 8894-8900, 2013.
Article in Chinese | WPRIM | ID: wpr-440401

ABSTRACT

BACKGROUND:In early experiments, we prepared hydroxyapatite-coated mechanical heart valve embedded with col agen using impulse laser sediment method. OBJECTIVE:To further analyze the histocompatibility and toxicity of hydroxyapatite-coated mechanical heart valve embedded with col agen. METHODS:After passage, canine vascular endothelial cellsuspension was inoculated onto the hydroxyapatite-coated mechanical heart valve embedded with col agen. One group was inoculated in 5%CO2, 37 ℃ incubator for 3 weeks static culture, and the other group was inoculated in 5%CO 2 , 37 ℃ incubator for 3 weeks spinner culture. Scanning electron microscope was used to observe cellattachment on the material. 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay was used to the proliferative capacity of vascular endothelial cells cultured with the hydroxyapatite-coated mechanical heart valve embedded with col agen. RESULTS AND CONCLUSION:During the spinner culture, adherent cells were found on the surface of mechanical heart valve, and the cells distributed evenly and confluent at 21 days to cover the surface of the material. The number of adherent cells in the spinner culture was higher than that in the static culture. The cells during the static culture were aggregated and distributed irregularly. The mechanical heart valve exhibited no effects on the proliferation of canine vascular endothelial cells which grew wel . These findings indicate that the hydroxyapatite-coated mechanical heart valve embedded with col agen exert no effect on proliferation of vascular endothelial cells, has no toxicity and has good biocompatibility.

4.
Chinese Journal of Tissue Engineering Research ; (53): 566-570, 2009.
Article in Chinese | WPRIM | ID: wpr-406727

ABSTRACT

OBJECTIVE: To verify the biocompatibility between diamond-like carbon (DLC) film and human vascular endothelial cells and to provide evidences for construction of artificial mechanical valve prosthesis. METHODS: Nanophase DLC film was deposited using pulse laser deposition, while vascular endothelial cells derived from human umbilical vein was cultured with nanophase DLC film in vitro. Cell growth and adhesion were observed under inverted microscope, and cell proliferation was measured with MIT method. In addition, levels of nitric oxide (NO) and prostacyclin (PGI2) were measured in the DLC group and blank control group in order to evaluate their activities. RESULTS: Adhesion, proliferation, and growth of vascular endothelial cells derived from human umbilical vein were great on the surface of nanophase DLC film. There were no significant differences in the levels of NO and PGI2 between DLC group and blank control group (P > 0.05), showing that nanophase DLC film had no effect on activity of vascular endothelial cells derived from human umbilical vein. CONCLUSION: Nanophase DLC film has a good biocompatibility, and it can become an ideal material of tissue-engineering artificial mechanical valve prosthesis.

5.
Chinese Journal of General Surgery ; (12)1997.
Article in Chinese | WPRIM | ID: wpr-518950

ABSTRACT

ObjectiveTo investigate the incidence, clinical features and preventive measurement of secondary hepato-biliary neoplasm (HBN) in patients with hepatolithiasis. MethodA clinical retrospective study was made on 27 hepatobiliary malignancy patients found among 556 consecutively admitted cases of hepatolithiasis from Jan. 1996 to Sep. 2000.Results The average incidence of hepatobiliary malignancy in patients with hepatolithiasis is 4.8%. In this series, preoperative definite diagnosis was made in 4 cases (4/27, 14.8%). Atypical liver abscess, refractory biliary system infection, progressive obstructive jaundice, CT or BUS scan abnormal findings, and epigastric masses are all clues to concurrent malignancy in patients of hepatolithiasis. ConclusionThere is high incidence of hepatobiliary malignancy in hepatolithiasis patients. Prophylactic partial hepatectomy for segments with stone and chronic infection may be an important measure to prevent ensuing malignancy.

SELECTION OF CITATIONS
SEARCH DETAIL