Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Imaging Technology ; (12): 56-59, 2010.
Article in Chinese | WPRIM | ID: wpr-473380

ABSTRACT

Objective To investigate the characteristics of fractional anisotropy (FA) and apparent diffusion coefficient (ADC) of association fiber tracts in patients with amnestic mild cognitive impairment (aMCI), and to assess the application value of diffusion tensor imaging (DTI) in differential diagnosis of aMCI and AD. Methods DTI were performed in 20 patients of aMCI (aMCI group), 20 patients of AD (AD group) and 20 normal control subjects (control group). FA and ADC values were calculated in the regions of interest (ROI) in inferior fronto-occipital fasciculus (IFOF), genu and splenium of corpus callosum, superior longitudinal fasciclesⅡ (SLFⅡ) and cingulated bundles. Results There was significant difference of FA values in inferior fronto-occipital fasciculus and cingulate bundles between aMCI group compared with control group (P<0.05), as well as of FA values in cingulate bundles between aMCI group and AD group (P<0.05). Conclusion Abnormal FA values in inferior fronto-occipital fasciculus and cingulate bundles suggest that DTI can be used as a diagnosis index of aMCI. Furthermore, it is helpful in the differential diagnosis of aMCI and AD.

2.
Chinese Journal of Medical Instrumentation ; (6): 180-182, 2010.
Article in Chinese | WPRIM | ID: wpr-281131

ABSTRACT

<p><b>OBJECTIVE</b>To compare the performance of three different types of RF coil in 3.0T MRI, the signal-to-noise ratio (SNR) and image uniformity in 3.0 Tesla magnetic resonance imaging system have been studied.</p><p><b>MATERIALS AND METHODS</b>In addition to the measurement of SNR and Uniformity based on the protocol recommend by AAPM, the images had also been analyzed using SPSS and MATLAB to get the SNR distribution along two vertical direction and the whole imaging plane.</p><p><b>RESULTS</b>The SNR with T/R birdcage coil and 8-ch surface coil is seven and twelve times higher than surface coil in the region of interest (ROI), which was set in the center of the phantom images. With regard to the spatial variation of sensitivity, the uniformity of T/R birdcage coil and 8-ch surface coil are also much higher than that of surface coil.</p><p><b>CONCLUSION</b>The images from T/R birdcage and phased array coils are all better than those of surface coil. The SNR of the images from phased array coil is highest while the uniformity of the images from T/R birdcage coil is highest.</p>


Subject(s)
Magnetic Resonance Imaging , Materials Testing , Methods , Phantoms, Imaging , Radio Waves , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL