Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Journal of Southern Medical University ; (12): 1683-1688, 2015.
Article in Chinese | WPRIM | ID: wpr-232546

ABSTRACT

<p><b>OBJECTIVE</b>To investigate the value of serum IgA/C3 ratio in the diagnosis of IgA nephropathy and explore its relationship with the clinicopathological features of the patients.</p><p><b>METHODS</b>Sixty-six patients with IgA nephropathy, 111 with other glomerular diseases, and 40 healthy control subjects without kidney disease were tested for serum IgA and C3 levels using CRM470 adjusted standardized immune turbidimetric method, and the IgA/C3 ratio was calculated. According to Oxford and Lee's classification criteria, we analyzed the pathological grades of the renal biopsy samples from patients with IgA nephropathy. The ROC curve was used to assess the value of serum IgA and IgA/C3 ratio in predicting IgA nephropathy.</p><p><b>RESULTS</b>Patients with IgA nephropathy had an elevated serum IgA/C3 ratio than those with other glomerular diseases and the control subjects, with an area under the ROC curve of 0.776. An elevated serum IgA/C3 ratio was not found to significantly correlate with the pathological grade of renal biopsy samples in patients with IgA nephropathy.</p><p><b>CONCLUSION</b>In the absence of renal biopsy findings, serum IgA/C3 ratio can help in the diagnosis of IgA nephropathy.</p>


Subject(s)
Humans , Biopsy , Case-Control Studies , Complement C3 , Glomerulonephritis, IGA , Blood , Diagnosis , Immunoglobulin A , Blood , Kidney , Pathology
2.
Journal of Audiology and Speech Pathology ; (6): 585-589,590, 2013.
Article in Chinese | WPRIM | ID: wpr-598736

ABSTRACT

Objective To explore the effects of different probe tone and tympanometric admittance measure-ment methods on the diagnose of otitis media prediction ,and to provide a clinical reference for the selection of probe tones and measurement method to apply to newborn infants .Methods Tympanograms with 226 Hz and 1 000 Hz probe tones were obtained from normal infants (142 ears) and infants with otitis media (90 ears) .Mean values , standard deviations ,the 90% range and 95% mean confidence interval were recorded as the variable to observe po-tential impacts on tympanometric admittance with 226 Hz probe tone and tympanometric peak admittance with 1 000 Hz probe tone by three different measurement methods respectively according to Linder/Jerger classification ,the Baldwin classification and baseline classification adapted from Baldwin .The four indexes were tested with compara-tive analysis .The area under ROC curve simultaneous detects the normal group and otitis media group ,with refer-ences to the accuracy of the detection method to disease (including specificity and sensitivity ) .Results In 1-to -3 month group ,tympanometric admittance with 226 Hz probe tone and tympanometric peak admittance with 1 000 Hz probe tone by three different measurement methods were 0 .83 ± 0 .29 ,0 .60 ± 0 .55 ,0 .74 ± 0 .56 ,0 .90 ± 0 .59 in nom-al infants and 0 .82 ± 0 .35 ,0 .01 ± 0 .06 ,-0 .24 ± 0 .15 ,-0 .29 ± 0 .21 in infants with OME ,respectively .The areas under ROC curve of the four kinds of measurement methods were 0 .507 ,0 .896 ,0 .976 ,0 .988 ,respectively .In 4 to 6 month group ,tympanometric admittance with 226 Hz probe tone and tympanometric peak admittance with 1 000 Hz probe tone by three different measurement methods were 0 .60 ± 0 .35 ,0 .55 ± 0 .58 ,0 .76 ± 1 .0 ,0 .86 ± 0 .72 in nomal infants and 0 .36 ± 0 .24 ,0 ± 0 ,-0 .34 ± 0 .16 ,-0 .44 ± 0 .28 in infants with OME ,respectively .The areas under ROC curve of the four kinds of measurement methods were 0 .749 ,0 .888 ,0 .969 ,0 .988 in 4 to 6 month infants ,re-spectively .Tympanometric peak admittance with 1 000 Hz probe tone by three different measurement methods were significantly better than that with 226 Hz probe tone .The areas under ROC curve of tympanometric peak admittance with 1 000 Hz probe tone by baseline classification adapted from Baldwin were bigger than others and the differences were significant(P0 .05) .Conclusion Tympanometric peak admittance with 1 000 Hz probe tone were better than that with 226 Hz probe tone to assess otitis media in 1~6 month infants .The baseline classification adapted from Baldwin was appropriate for the measurement of tympanometric peak admittance with 1 000 Hz probe tone .

3.
Journal of Clinical Otorhinolaryngology Head and Neck Surgery ; (24): 371-375, 2013.
Article in Chinese | WPRIM | ID: wpr-749525

ABSTRACT

OBJECTIVE@#To analyze the judgement standard and evaluate the diagnostic value of the low frequency and high frequency tympanometry in infants with otitis media.@*METHOD@#Tympanograms for admittance with 226 Hz and 1 000 Hz probe tones and resonant frequency were obtained from normal infants (195 cases, 321 ears) and infants with otitis media(122 cases, 171 ears). The mean, standard deviation, median, 5% quantile, 95% quantile and 95% confidence interval of peak admittance, gradient and resonant frequency were measured and calculated in different age groups. The significant differences of 1000 Hz peak admittance, 226 Hz peak admittance and gradient between normal infants and infants with otitis median were analyzed using SPSS 11.0. The false positive rate and the false negative rate of different age groups in infants with otitis media were evaluated according to such judgement standards as 1000 Hz peak admittance, 226Hz peak admittance or gradient.@*RESULT@#The false positive rate and the false negative rate of the 1000 Hz probe tone tympanometry in infants with otitis media unter one year of age were 3.07% and 1.84% as the normal range of positive peak was more than 0.2 mmho. The false positive rate and the false negative rate of the 1000 Hz probe tone tympanometry in infants with otitis media aged 1-2 years and aged 2-3 years were 3.26%, 5.26% and 1.52%, 0.00% respectively,as the normal range of positive peak was more than 0.3 mmho. These was no significant difference in the gradient with 226 Hz probe tone between normal infants and infants with otitis median under one year of age. The false positive rate and the false negative rate of the 226 Hz probe tone tympanometry in infants with otitis media aged 1-2 years and aged 2-3 years were 44.57%, 31.58% and 16.67%, 6.67% respectively, as the gradient with 226 Hz probe tone was a judgement standard.@*CONCLUSION@#(1) The diagnostic accuracy of tympanometry with 1000 Hz probe tone for otitis media in infants younger than 3 years of age exceeded 226 Hz probe tone tympanometry, the 1000 Hz probe tone tympanometry is suggested to the evaluation of middle ear function in infants before 3 years. (2) It is reasonable that the normal range of positive peak is more than 0.2 mmho in infants unter one year of age and the normal range of positive peak is more than 0.3 mmho in infants aged 1-3 years.


Subject(s)
Humans , Infant , Infant, Newborn , Acoustic Impedance Tests , Methods , Case-Control Studies , Otitis Media , Diagnosis , Reference Values
4.
Journal of Audiology and Speech Pathology ; (6): 593-595, 2013.
Article in Chinese | WPRIM | ID: wpr-441846

ABSTRACT

Objective To investigate the characteristics of click -auditory brainstem response (ABR) in nor-mal infants of 1 to 6 months old ,and to establish the normative values for latencies of Wave I ,III ,V and interpeak latencies of I- Ⅲ ,III-V and I-V for younger infants .Methods Click auditory brainstem responses were recorded from infants within 6 months :166 infants of 1 -months old(269 ears) ,141 2 -month old (226 ears) ,111 3 -months old(177 ears) ,58 4-months old(96 ears) ,78 5-months old(121 ears) and 45 6-months old(76 ears) .We compared the latencies of wave I ,III ,V and interpeak latencies of I - Ⅲ ,III-V ,I-V obtained from infants of differ-ent ages at different stimulus intensities .Results The average threshold of 1 to 6 months infants was 16 .18 ± 5 .35 dB nHL ,the average latency of Wave V was 9 .03 ± 0 .49 ms .The differences among the thresholds were statistical-ly insignificant(P>0 .05) .Wave I ,III and V were noticeable in all ears tested at 80 dB nHL .Wave I disappeared first as the stimulus intensity decreased ,and the latencies of Wave I ,III and V prolonged;on the contrary ,interpeak latencies of I -III ,III-V ,I-V shortened significantly .At the same stimulus intensity ,the latencies of Wave III , V and the interpeak latencies of I - Ⅲ ,III-V ,I-V shortened significantly except for Wave I .When comparing the differences among the testing parameters as a function of each month ,we found that there were statistically signifi-cant differences for the latencies of wave III ,V and the interpeak latencies of I -III ,III-V ,I-V before the 4 months old(P0 .05) .Conclusion It is recommen-ded that 16 .18 ± 5 .35 dB nHL be used as the normative references for the evoked threshold of click auditory brain-stem responses for 1~6 month old infants .The development of central nervous system below the inferior calicles is fast before the 4 months old .

SELECTION OF CITATIONS
SEARCH DETAIL