Chinese Journal of Blood Transfusion ; (12): 1377-1379, 2021.
Article in Chinese | WPRIM | ID: wpr-1003986

ABSTRACT

【Objective】 To observe the application of the traditional and modified catheter transfer method in leukocyte-depleted blood preparation and the effect of modified method on reducing the blood discard rate due to hot joint leakage. 【Methods】 After leucocyte filtration, the traditional method is to seal the product bag catheter directly and then connect the whole blood catheter, while the modified method is to seal the two sections on the product bag catheter and then connect the whole blood catheter at the distal seal. The blood discard rates of the two methods due to the hot joint leakage in the catheter connection of leukocyte reduction were analyzed. 【Results】 After repeated training for the staff, using the same type of equipment, the blood discard rate due to heat sealing leakage by modified method was 0(0/33 595), significantly lower than that by traditional method(0.11%, 36/32 873, P<0.001). 【Conclusion】 The modified method can significantly reduce the discard rate of blood due to seal leakage and save valuable blood resources. However, there is still a risk of seal leakage, and staff should take preventive measures against occupational exposure