Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Experimental Ophthalmology ; (12): 55-62, 2023.
Article in Chinese | WPRIM | ID: wpr-990809

ABSTRACT

Objective:To detect the concentration of various cytokines in aqueous humor of patients with diabetes retinopathy (DR) with Luminex liquid chip, and analyze the relationship between the cytokines and the occurrence and development of DR.Methods:A cross-sectional study was conducted.Sixty-three DR patients (97 eyes) treated with anti-vascular endothelial growth factor (VEGF) drugs in the First Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine from March 1, 2019 to December 31, 2019 were enrolled as DR group, including 38 nonproliferative DR (NPDR) eyes in NPDR group and 59 proliferative DR (PDR) eyes in PDR group, 39 eyes in photocoagulation group and 58 eyes in non-photocoagulation group.Twenty-seven patients (31 eyes) hospitalized for cataract surgery at the same time were collected as the control group.Aqueous humor was extracted during the operation, and Luminex liquid chip was used to detect the concentrations of vascular endothelial growth factor-A (VEGF-A), placental growth factor (PLGF), platelet-derived growth factor (PDGF)-AA, PDGF-BB, angiopoietin-like protein 4 (ANGPTL4), interleukin-6 (IL-6), IL-8, IL-1β, monocyte chemotactic protein-1 (MCP-1), intercellular cell adhesion molecule-1 (ICAM-1) and tumor necrosis factor-α (TNF-α) in aqueous humor.The concentrations of various cytokines of different groups were compared, and the correlation among various aqueous humor cytokines was analyzed by Spearman rank correlation analysis.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of First Affiliated Hospital of Guangzhou University of Chinese Medicine (No.Y[2019]230). Written informed consent was obtained from each patient.Results:The concentrations of VEGF-A, PLGF, PDGF-AA, ANGPTL4, IL-6, IL-8, MCP-1 and ICAM-1 in DR group were significantly higher and the concentration of IL-1β was significantly lower than those of control group ( Z=-4.747, -5.164, -3.373, -8.062, -4.535, -5.954, -5.098, -3.228, -5.954, all at P<0.01). The concentrations of VEGF-A, PLGF, PDGF-AA, ANGPTL4, IL-6, IL-8 and MCP-1 of the photocoagulation and non-photocoagulation groups were higher and the concentration of IL-1β was significantly lower than those in the control group (all at P<0.017). The concentration of ICAM-1 in the photocoagulation group was significantly higher than that in the control group ( P<0.017). The concentrations of PLGF, PDGF-AA and ANGPTL4 of PDR group were higher than those of NPDR group, and the differences were statistically significant ( Z=-2.291, -3.396, -2.276, all at P<0.05). VEGF-A was positively correlated with the other cytokines except ICAM-1 ( rs=0.237-0.540, all at P<0.05). ANGPTL4 was positively correlated with the other cytokines except IL-1β ( rs=0.361-0.733, all at P<0.01). Conclusions:The occurrence and development of DR are closely related to VEGF family, PDGF family, ANGPTL family and inflammatory factors.The concentrations of PLGF, PDGF-AA and ANGPTL4 are higher in PDR eyes.There are close and complex relationships among a variety of cytokines in the eyes of DR patients.

2.
Chinese Journal of Practical Nursing ; (36): 1-3, 2009.
Article in Chinese | WPRIM | ID: wpr-393461

ABSTRACT

Objective To explore the influence of different testing methods on detecting value of to-tal cell volume. Methods 60 reusable dialyzers(low-flux dialyzer and high-flux dialyzer were 30 respec-tively) were enrolled. They were divided into the traditional testing group, the modified testing group and the automatic dialyzer reuse group with 20 dialyzers in each group according to different detecting methods, the results underwent analysis. Results The basic total cell volume of the traditional testing group, the modified testing group and the automatic dialyzer reuse group were (100.10±0.25) ml, (100.13±0.50) ml and (102.00±1.41) ml in 6LR dialyzer, while in 17R dialyzer, they were (113.67±1.30) ml, (118.67±1.30) ml and (119.93±1.77)ml respectively. The total cell volume of the dialyzer reuse in the traditional testing group, the modified testing group and the automatic dialyzer reuse group were (95.20±7.76) ml, (96.20± 7.22) ml and (102.80±4.26) ml in 6LR dialyzer, while in 17R dialyzer, they were (100.00±11.48) ml, (114.35±3.31 ) ml and (117.07±2.96) ml respectively. There was significant difference between the tradi-tional and the modified testing groups in high-flux dialyzers reuse. Conclusions The modified testing method can improve the accuracy of the testing of total cell volume in high-flux dialyzer reuse.

SELECTION OF CITATIONS
SEARCH DETAIL