Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Pharmacology and Therapeutics ; (12): 139-145, 2024.
Article in Chinese | WPRIM | ID: wpr-1014554

ABSTRACT

AIM: To observe the effect of RBC preservation solution with sodium pyruvate on the morphology, structure and function of RBC stored in vitro in type 2 diabetes rats. METHODS: Thirty SPF male SD rats, were randomly divided into 3 groups (n=10): non-T2DM conventional RBC preservation solution (group A), T2DM conventional RBC preservation solution (group B) and T2DM sodium pyruvate RBC preservation solution (group C). The leukoreduced RBC from the tail vein and stored for 0 d (T0), 7 d (T1), 14 d (T2), 21 d (T3) and 28 d (T4) to detect the morphology, structure and the contents of 2, 3-DPG, reactive oxygen species (ROS), malondialdehyde (MDA) and lactic acid (LA) of RBC in group A, B and C. The RBC stored for 14 days in vitro were labeled with PKH26, and its survival rate were tested in vivo at 1, 4, 10 and 16 hours after intravenous infusion. RESULTS: At T0, the RBC morphology of group A was intact, which was better than that of group B and group C. With the extension of storage time, the morphology of RBC in each group gradually transformed into a spindle-spherical shape. Compared with group A, the incidence of acanthocytes in group B and group C was higher, and the incidence of acanthocytes in group C was lower than that in group B. Compared with group A, the content of 2, 3-DPG in group B and group C decreased, while ROS and MDA increased at different time points (P<0.05). The content of 2,3-DPG in group C was higher than that in group B (P<0.05), and the contents of ROS and MDA were lower than those in group B (P<0.05). LA content in group B was higher than that in group A and group C (P<0.05). At T2-T4, the LA content in group C was lower than that in group A (P<0.05). The survival rate of RBC in group A was higher than that in group B and C, and the survival rate of RBC in group B was lower than that in group C (P<0.05). CONCLUSION: Sodium pyruvate added RBC preservation solution has a certain protective effect on RBC stored in vitro in type 2 diabetic rats, and its mechanism may be related to its antioxidant effect.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 80-84, 2022.
Article in Chinese | WPRIM | ID: wpr-912996

ABSTRACT

@#Objective    To evaluate the data of preoperative aortic root CT angiography (CTA), compare it with two-dimensional transthoracic echocardiography and investigate the correlation of the two measurements with the actual intraoperative measurement data. Methods    Clinical data of 53 patients with aortic valve diseases who underwent aortic valve repair in our hospital from January 2018 to August 2020 were retrospectively analyzed, including 38 males and 15 females with an average age of 42.9±18.3 years ranging from 10 to 77 years. Preoperative two-dimensional transthoracic echocardiography (TTE) and aortic root CTA measurements were collected, including aortic valve annulus (AVA), aortic sinus (Sinus) and sino-tubular junction (STJ). In comparison with the intraoperative measurements during the aortic valve repair surgery, the consistency analysis was performed. Results    Both the preoperative echocardiography AVA measurements and the CT AVA measurements were positively correlated with the intraoperative AVA measurements (P<0.001). Compared with the echocardiography AVA data [correlation coefficient (ρ)=0.74, mean squared error (MSE)=12.78], the CT AVA data were more accurate and consistent with the intraoperative AVA measurements (ρ=0.95, MSE=2.72). CT AVA data had a higher correlation coefficient with the intraoperative measurements, compared to that of  the echocardiography AVA data (P<0.001). Conclusion    In comparison with two-dimensional transthoracic echocardiography, preoperative morphological evaluation of aortic root CTA is more consistent with the actual intraoperative measurements during aortic valve repair surgery.

3.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1436-1440, 2021.
Article in Chinese | WPRIM | ID: wpr-906588

ABSTRACT

@#Objective    To evaluate the short and mid-term outcomes of valve repair in patients with insufficient bicuspid aortic valves (BAV). Methods    The clinical data of 27 consecutive patients with insufficient BAV undergoing valve repair in Shanghai Chest Hospital from September 2016 to January 2020 were retrospectively reviewed. There were 24 males and 3 females with a mean age of 38.5±14.6 years (range: 20-68 years). BAV of all patients was type 1 in Seviers' classification. There were 23 patients with left-right fusion and 4 patients with right-noncoronary fusion. There was aortic regurgitation in the patients measured by the echocardiogram, including moderate regurgitation in 3 patients, moderate-severe in 18 patients, and severe in 6 patients. The diameter of aortic annular base was 27.9±3.4 mm, and the largest diameter of aortic sinus was 39.9±7.6 mm. Left ventricular end diastolic diameter was 62.7±6.5 mm, and the volume was 197.9±53.6 mL. Results    All 27 patients completed the follow-up, and the mean time was 24.2±12.5 months (range: 12-51 months). No patient died or required aortic valve-related reoperation during the follow-up. The cardiac function of the patients significantly improved postoperatively (P<0.05). By echocardiography, 11 patients had no aortic regurgitation, 13 had mild aortic regurgitation, and 3 had moderate aortic regurgitation, and no patient had severe aortic regurgitation. Postoperative left ventricular end diastolic diameter and volume decreased, compared to preoperative ones (P<0.05). Conclusion    In patients with insufficient BAV, valve repair is safe and effective, and has excellent short and mid-term outcomes.

4.
Chinese Journal of Medical Imaging Technology ; (12): 79-81, 2010.
Article in Chinese | WPRIM | ID: wpr-471720

ABSTRACT

Objective To investigate the preliminary value of mitral annular displacement (MAD) with two-dimensional speckle tracking in evaluating left ventricular systolic function. Methods Forty-nine patients with dilated cardiomyopathy, aged 51±14 years (DCM group), and 43 age-matched (46±14 years) normal subjects (control group) were enrolled in this study. Two-dimensional and real-time three-dimensional (RT3D) imaging were obtained all at the apical four-chamber view. The parameters of MAD and RT3D-LVEF were obtained using off-line QLAB software. Results Compared with control group, MAD reduced significantly in DCM group (P<0.01). The parameters of MAD correlated positively with LVEF (P<0.01). The intra- and inter-observer variabilities for measurement of MAD were low. When one point was placed at the chest wall, the ratio of long axis shortening correlated best with LVEF among all the data of MAD. Conclusion Based on two-dimensional speckle tracking imaging, MAD is a rapid and reproducible method of determining LV global systolic function, may even replace LVEF in the future.

5.
Chinese Journal of Ultrasonography ; (12): 1034-1036, 2009.
Article in Chinese | WPRIM | ID: wpr-391752

ABSTRACT

Objective To determine the usefulness of tricuspid annular displacement(TAD),based on twodimensional speckle tracking imaging, for assessment of right ventricular(RV)systolic function.Methods Eighteen patientswith dilated cardiomyopathy and 20 age-matched healthy volunteers were in volved. Twodimensional and real-time three-dimensional(RT3D)imaging were obtained in all patients at apical four-chamber view.The parameters of TAD were derived from off-line QLAB software.RT3D-RV ejection fraction(RVEF)was calculated by using 4D RV function software.Results TAD data were acquired in all 38 cases, while RT3D-RVEF was done in 30 out of 38.The parameters of TAD correlated well with RVEF(P<0.01).The parameters of TAD in dilated cardiomyopathy group were significantly lower than the corresponding values in healthy subjects (P<0.01).The intra-and interobserver variabilities for measurement of TAD were(0.49±2.69)mm and(0.21± 0.60)mm, respectively.Conclusions TAD,based on two-dimensional speckle tracking imaging,proved to be a rapid and reproducible method in determining RV global systolic function.

SELECTION OF CITATIONS
SEARCH DETAIL