Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Otorhinolaryngology Head and Neck Surgery ; (12): 561-565, 2017.
Article in Chinese | WPRIM | ID: wpr-809141

ABSTRACT

Objective@#To discuss the prediction of round window(RW) visibility in cochlear implantation(CI) with temporal bone high resolution computed tomography(HRCT).@*Methods@#From January 2013 to January 2017, 130 cases underwent both HRCT and CI in our hospital were analyzed. The distance from facial nerve to posterior canal wall(FWD), the angle between facial nerve and inner margin of round window(FRA), and the angle between facial nerve and tympanic anulus to inner margin of round window(FRAA) were detected at the level of round window on axial temporal bone HRCT. A line parallel to the posterior wall of ear canal was drawn from the anterior wall of facial nerve at the level of round window on axial temporal bone HRCT and its relationship with round window was detected (facial-round window line, FRL): type0-posterior to the round window, type1-between the round window, type2-anterior to the round window. Their(FWD, FRA, FRAA, FRL) relationships with intra-operative round window visibility were analyzed by SPSS 17.0 software.@*Results@#FWD(F=18.76, P=0.00), FRA(F=34.57, P=0.00), FRAA (F=14.24, P=0.00) could affect the intra-operative RW visibility significantly. RW could be exposed completely during CI when preoperative HRCT showing type0 FRL. RW might be partly exposed and not exposed when preoperative HRCT showing type1 and type2 FRL respectively.@*Conclusion@#FWD, FRA, FRAA and FRL of temporal bone HRCT can predict intra-operative round window visibility effectively in CI surgery.

2.
Chinese Journal of Otorhinolaryngology Head and Neck Surgery ; (12): 283-286, 2017.
Article in Chinese | WPRIM | ID: wpr-808535

ABSTRACT

Objective@#To discuss the possible reasons for cerebrospinal fluid (CSF) gusher in cochlear implantation (CI) with inner ear abnormality.@*Method@#A retrospective analysis was performed on 340 cases who underwent CI from January 2013 to December 2016 in Division of Otology, Otorhinolaryngology Hospital, the First Affiliated Hospital of Zhengzhou University. Among them, 96 cases had inner ear abnormalities. Imaging examinations were performed on these patients, and classification of inner ear malformation was done according to the results.@*Results@#Among the cases with inner ear abnormality, 9.4% (9/96) suffered from CSF gusher during CI. The inner ear abnormalities were found to be as follows: 3 cases had incomplete partition type Ⅰ; 1 case had incomplete partition type Ⅰ with semicircular canal dysplasia; 1 case had common cavity deformity; 1 case had enlarged vestibular aqueducts and common cavity deformity; 2 cases had Mondini deformity. All of these cases had bony defect in the fundus of the internal acoustic meatus observed on CT scans. Another case was type 1 cochlear aqueduct with round window aplasia.@*Conclusions@#Defects in the modiolus or fundus of the internal acoustic meatus is the main reason for CSF gusher during CI. A patent cochlear aqueduct is another possible reason.

3.
Chinese Journal of Microsurgery ; (6): 349-352, 2017.
Article in Chinese | WPRIM | ID: wpr-615570

ABSTRACT

Objective To discuss the clinical characteristic of middle ear malformation with cholesteatoma.Methods From September,2011 to November,2016,23 cases of middle ear malformation with cholesteatoma were collected.Their symptoms,ENT examination,temporal bone high resolution computed tomography (HRCT) and intraoperative findings were analyzed.Results All 23 patients had hearing loss.90.0% patients had ear discharge and tinnitus.86.96% patients had perforation in pars flaccida of tympanic membrane.95.7% patients had poor mastoid gasification.73.9% patients had undeveloped or dysplastic tympanic antrum.100% patients had destruction of the ossicular chain.56.5% patients had malformation of the ossicular chain.52.2% patients had exposed facial nerve.30.4% patients had hyperplasia of the attic bone.Conclusion The symptoms and physical examinations of middle ear malformation with cholesteatoma are the same as middle ear cholesteatoma.Poor mastoid gasification can usually be detected on temporal bone HRCT.The most common malformation is dysplastic tympanic antrum,followed by malformation of the ossicular chain,exposed facial nerve and hyperplasia of the attic bone.Temporal bone HRCT can indicate the malformation and destruction quite well.

4.
Journal of Audiology and Speech Pathology ; (6): 296-299, 2017.
Article in Chinese | WPRIM | ID: wpr-613975

ABSTRACT

Objective To investigate the development of auditory and speech skills and the safety and stability among the prelingually deaf children with Nurotron Venus cochlear implants.Methods A total of 78 cochlear implant subjects were recruited from the first of affiliated hospital of Zhengzhou university.They were divided into 5 groups according to the ages at the time of implantation: group A(between 13 and 24 months), group B(between 25 and 36 months),group C(between 37 and 48 months),group D(between 49 and 72 months),group E(between 73 and 96 months).Children were evaluated by IT-MAIS(group A and B) and MAIS(group C,D and E) before the surgery and 1 month,3 months,6 months, and 12 months after surgery.All children were evaluated by MUSS questionnaires 1 months, 3 months,6 months,and 12 months after surgery.Post-operative cochlear radiographs determine the position of the CIs.The complications and usage of The CIs were followed up.Results The auditory and speech ability of children with CIs improved constantly.The auditory and speech of different groups were statistically significant.All the surgeries of 78 cases Nurotron-Venus cochlear implants were successful.Post-operative cochlear radiographs showed electrodes in the normal position.2 cases had processor failures.The remaining CIs were implanted completely.Conclusion Within 1 year, the ability of auditory and speech improved gradually.The scores of auditory and speech about the small age groups are lower than older children in the early days.There is no influence on the audition in 12 months.Small children's scores of speech are lower than older children in 12 months.The better ability to integrate auditory information is , the better the ability to speak is.The Nurotron CIs work safety and effectively.

SELECTION OF CITATIONS
SEARCH DETAIL