Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Veterinary Science ; : e80-2020.
Article | WPRIM | ID: wpr-833739

ABSTRACT

Background@#In suckling piglets, transmissible gastroenteritis virus (TGEV) causes lethal diarrhea accompanied by high infection and mortality rates, leading to considerable economic losses. This study explored methods of preventing or inhibiting their production.Bovine antimicrobial peptide-13 (APB-13) has antibacterial, antiviral, and immune functions. @*Objectives@#This study analyzed the efficacy of APB-13 against TGEV through in vivo and in vitro experiments. @*Methods@#The effects of APB-13 toxicity and virus inhibition rate on swine testicular (ST) cells were detected using 3-(4,5-dimethylthiazol-2-yl)-2, 5-diphenyl tetrazolium bromide (MTT). The impact of APB-13 on virus replication was examined through the 50% tissue culture infective dose (TCID50 ). The mRNA and protein levels were investigated by real-time quantitative polymerase chain reaction and western blot (WB). Tissue sections were used to detect intestinal morphological development. @*Results@#The safe and effective concentration range of APB-13 on ST cells ranged from 0 to 62.5 µg/mL, and the highest viral inhibitory rate of APB-13 was 74.1%. The log10 TCID50 of 62.5 µg/mL APB-13 was 3.63 lower than that of the virus control. The mRNA and protein expression at 62.5 µg/mL APB-13 was significantly lower than that of the virus control at 24 hpi. Piglets in the APB-13 group showed significantly lower viral shedding than that in the virus control group, and the pathological tissue sections of the jejunum morphology revealed significant differences between the groups. @*Conclusions@#APB-13 exhibited good antiviral effects on TGEV invivo and in vitro.

2.
Chinese Journal of Nosocomiology ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-594664

ABSTRACT

OBJECTIVE To understand disinfection quality in newborn Spa room,to give prevention messures against nosocomial infection.METHODS The air,UV intensity,the object surface,staff′s hands,and the using of disinfectant were detected.RESULTS The total qualified rate was 98.61% and that of the object surface was 97.22%,of staff′s hands was 98.61%,of UV intensity and indoor air was 100% and of the using disinfectant was 97.22%.CONCLUSIONS Strengthening the disinfection,finding the weak timely and taking the effective measures can prevent the occurrence of hospital infection.

SELECTION OF CITATIONS
SEARCH DETAIL