Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Postgraduates of Medicine ; (36): 1080-1083, 2022.
Article in Chinese | WPRIM | ID: wpr-990941

ABSTRACT

Objective:To compare the effects of modified incision drainage combined with thread-drawing and precise minimally invasive surgery in the treatment of anal fistula on anal defecation function and complications.Methods:A total of 105 patients with anal fistula who were diagnosed and treated in Xin′an International Hospital from December 2018 to December 2020 were collected. The patients were divided into the observation group (58 cases) and the control group (47 cases) according to surgical methods. The observation group received modified incision drainage combined with thread-drawing surgery. The control group received precise minimally invasive anal fistula surgery. The treatment outcome, anal defecation function and complications were compared between the two groups.Results:The operation time, intraoperative blood loss, first defecation time after operation, normal eating time after operation in the two groups had no significant differences ( P>0.05). The hospital stay in the observation group was significantly longer than that in the control group: (5.29 ± 1.53) d vs. (4.02 ± 1.16) d, there was statistical differences ( P<0.05). After operation, the resting pressure of the anal canal, resting rectal pressure, length of the tube high pressure belt, the maximum systolic pressure of the anal canal between the two groups had no significant differences ( P>0.05). The excellent and good rate of anal defecation function and complication rate between the two groups had no significant differences ( P>0.05). Conclusions:Modified incision drainage combined with thread-hanging surgery in the treatment of anal fistula is equivalent with precision minimally invasive surgery. Both can effectively improve the anal defecation function. The postoperative safety is good and there is no recurrence. However, the hospital stay of patients with precision minimally invasive surgery for anal fistula is relatively shorter.

2.
Military Medical Sciences ; (12): 818-821, 2013.
Article in Chinese | WPRIM | ID: wpr-439997

ABSTRACT

Objective To establish an LC-MS/MS method for determination of S-071031 B, a novel antidepressant , in rat plasma and to study its pharmacokinetic profiles .Methods An LC-MS/MS method was established to determine S-071031B in rat plasma, and L-8021 was employed as the internal standard .The analytes were separated on a C18 column with a mobile phase consisting of water-acetonitrile containing 0.1%(v/v) formic acid at a flow rate of 0.3 ml/min.The mass spectrometer was operated in a selected reaction monitoring ( SRM ) mode with a positive electrospray ionization (ESI) interface.The plasma concentration-time curve was drawn and pharmacokinetic parameters were calculated by DAS 2.0.Results The linear range was from 2 to 1000 ng/ml with a sensitivity of 2 ng/ml as the lower limit of quantification . The intra-day and inter-day precisions , recoveries and matrix effects at three spiked levels were all suited to the determina-tion of biological samples.After oral administration of S-071031B, the Cmax of S-071031B was (287.2 ±50.8) μg/L and the Tmax was (0.8 ±0.3) h, with a t1/2of (2.9 ±0.6) h and an AUC(0-∞)of (1372.6 ±255.3) μg/L· h.Conclusion This method is sensitive and specific enough for determination of S-071031 B in rat plasma to facilitate the study of its phar-macokinetics .

3.
Cancer Research and Clinic ; (6): 158-160, 2008.
Article in Chinese | WPRIM | ID: wpr-384021

ABSTRACT

Objective To develop a HPLC method for the determination of chlorogenic acid in xiaoaiping injection in human plasma.Methods The analytical column was packed with Hypersil ODS C18 (250 mm×4.6 nm,5 μm).The mobile phase was acetonitrile-0.4% phosphoric acid solution(13:87).The flow rate was 1 ml/min,and detection wave length was set at 327 nm.Results The linear ranges were 2.5~60.0 mg/L chlorogenic acid in human plasma,with the correlation coefficients of 0.9996.The Low limit of detection was 0.25 μg/ml.The method and extraction recovery were 100.1%~102.6%and 78.6%~80.3%.The relative standard deviation value for the within-day and between-day precision were less than 3.9%.Conclusion The method is simple,sensitive for the determination of chlorogenic acid in xiaoaiping injection in human plasma.

SELECTION OF CITATIONS
SEARCH DETAIL