Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Modern Urology ; (12): 841-845, 2023.
Article in Chinese | WPRIM | ID: wpr-1005970

ABSTRACT

【Objective】 To investigate the effects of lamellar surgical techniques with urethral plate to strengthen the tissue of glans penis to widen the two flanks of glans penis on the basis of Duckett method in the treatment of congenital hypospadias with small glans penis deformity. 【Methods】 A total of 22 patients admitted to our hospital during Jun.2017 and Oct.2020 were involved. Urethral plate was used to replace the glans penis tissue to widen the two flanks of glans penis based on Duckett method. Lamellar surgical techniques were adopted to fully dissociate the two flanks of glans penis and urethral plate for urethroplasty. 【Results】 Of the 22 operations, 19 were successful,with a success rate of 86.3%. The success rate of penile head urethroplasty reached 96.1%. 【Conclusion】 Widening the glans penis by using the urethral plate based on Duckett method combined with lamellar surgical techniques can improve the success rate of glans penis urethroplasty.

2.
Chinese Journal of Analytical Chemistry ; (12): 429-433, 2010.
Article in Chinese | WPRIM | ID: wpr-403186

ABSTRACT

A high performance liquid chromatographic method with fluorimetric detector was developed for the simultaneous determination of three sulfonamides in vegetable samples. Vegetable samples were extracted with methanol for three times, and then the combined extracts were evaporated to dryness under reduced pressure at 45 ℃. The residue was dissolved in 0.1 mol/L HCl and the analytes were derivatized with fluorescamine. The chromatographic separation was performed on an ODS column with a gradient elution program using mobile phases based on mixtures of acetonitrile and 0.5% acetic acid aqueous solution. The derivatized compounds were detected with fluorimetric detector. The limit of detection was 1.02-1.29 μg/L and the limit of quantification was 3.4-4.3 μg/kg(fresh weight, F.W.) for three sulfonamides in vegetable. The average recoveries were higher than 87%, inter and intra RSDs were lower than 10% for all samples spiked with 0.2-1.0 μg/g of sulfonamides. The proposed method has been applied to the analysis of vegetables sold in Hefei markets. The result indicated that 3 SAs were found at different degree in the practical vegetable samples with the total concentrations between 0.0726-0.3709 μg/g(F.W.).

SELECTION OF CITATIONS
SEARCH DETAIL