Journal of Modern Laboratory Medicine ; (4): 157-161, 2017.
Article in Chinese | WPRIM | ID: wpr-613488

ABSTRACT

Objective To build anautoverification system for hematology analysis system and validate the system based on commercialized labXpert software.Methods Preliminary validation rules was established base on 41 Items of International Consensus Review Rules and instructions for Mindray CAL8000 auto hematology analyzer,and input the rules into labX pert sample validation system.999 clinical samples were collected from Beijing Hospital Ministry of Health to test the preliminary rules and parameters including false positive rate,false negative rate and autoverification pass rate were calculated,based on which to adjust and customize the original protocol.Then 15 934 samples were tested,respectively,for autoverification by calculating the autoverification pass rate,proportion of manual verification and microscopic verification.Autoverification were compared as well as the turnover time (TAT,timefrom receipt of sample to report of result) before and after application of autoverification system.Results Preliminary verification results showed that false negative rates in both hospitals were less than 2%,and the false negative mainly caused by low promyelocytic cells value (blasts and promyelocytes less than 3 %),abnormal erythrocyte morphology,and abnormal platelet morphology.No sample with excess blasts or percentage of blasts and promyelocytes higher 3% with tested with false negative result,indicating relatively low clinical risks.Both hospitals reported with relatively high false positive rates,up to nearly 18%,using preliminary programs,which may affect the autoverification rate of the system.Based on the analyzing result of false positive results,the program was adjusted to significantly reduce the false positive rate while remaining the false negative rate low,therefore resulted with 4 remarkable increase of autoverification pass rate.Over 10,000 samples were tested with improved program,and the autoverification pass rates for hospital was 78.4 %,respectively.Primary reason causing failure of autoverification included increased IMG%,flag for immature cells and WBC exceeding set limit.Application of system reduced the TAT by 5 min (P<0.05).Conclusion Autoverificationsystem using Mindray CAL8000 auto hematology analyzer andlabXpert has been confirmed effective in reducing TAT and enhancing working efficiency while remaining low false negative rate.The autoverification pass rate tested 75%,which suggested that laboratory workers can spare more time on reexamination of abnormal samples for better blood routine report.

2.
Chinese Journal of Geriatrics ; (12): 986-989, 2016.
Article in Chinese | WPRIM | ID: wpr-502439

ABSTRACT

Objective To determine the normal reference values for thromboelastography (TEG) in Chinese healthy elderly people in Beijing and compare them with those provided by the manufacturer and with people under the age of 55 years.Methods The healthy elderly people aged over 65 years were enrolled from March 2014 to April 2014.4 ml of peripheral vein blood samples were taken from each person.All subjects underwent the laboratory tests of prothrombin time (PT),activated partial thromboplastin time (APTT),thrombin time (TT) and fibrinogen (FIB).TEG parameters including reaction time (R),coagulation time (K),angle (alpha) and maximum amplitude (MA) were determined by using a Heamoscope 5000 device.Results A total of 119 healthy elderly subjects were enrolled in this study.The mean values (95% CI) of TEG parameters for them were R:6.29 min (4.4-8.2 min),K:1.63 min (0.8-2.5 min),α-Angle:66.09° (55.0-77.1°),MA:63.43mm (54.5-72.3 mm).There were significant differences in the values of R,K and α-Angle between the elderly and non-elderly groups (P<0.001 or 0.05).There were significant differences in the values of K,α-Angle and MA between males and females (P<0.05 or 0.001).According to the normal reference values provided by the manufacturer,16.1% (19/119) of the healthy elderly volunteers had at least one abnormal parameter beyond its normal range.3% (3/119) of the healthy elderly people were diagnosed as coagulation abnormalities,yielding a specificity of 84%.Compared with normal reference values provided by the manufacturer,the value of R was lower and the value of MA was higher in the healthy elderly people in Beijing.Conclusions The normal reference values for TEG should be established based on the local population characteristics.

3.
Chinese Journal of Marine Drugs ; (6): 13-17, 2005.
Article in Chinese | WPRIM | ID: wpr-410019

ABSTRACT

Objective To search for triterpene glycoside with new structure. Methods We studied the sea cucumber Colochirous anceps belonging to the family cucumariidea with many chromatography methods and found a new sulfated triterpene glycoside, which structure was established by a combination of spectroscopic analysis (IR, UV, ESI-MS and 2D-NMR), chemical transformations and other chemical evidence. Results and Conclusion The new sulfated triterpene glycoside was isolated and named Colochiroside A (1) .