New Egyptian Journal of Medicine [The]. 1993; 8 (4): 963-70
in English | IMEMR | ID: emr-29748

ABSTRACT

This work was carried out in Orthopedic Department, Mansoura University Hospital since 1987. 48 patients with 66 fractures and 22 fracture proximal phalanx were treated by O.R.I.F. by mini plate and screws. Results were evaluated. It was proved that this is a good method of treatment of hand fractures. Factors affecting the end results were recorded