Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Nuclear Medicine ; (6): 291-294, 2010.
Article in Chinese | WPRIM | ID: wpr-643377

ABSTRACT

Objective To investigate the changes of early and delayed washout rates of 99Tcm-methoxyisobutylisonitrile (MIBI) in ischemic heart disease (IHD), and to explore the value of 99Tcm-MIBI SPECT in evaluating impairment of ischemic myocardial cells. Methods Patients diagnosed of IHD with three-vessel stenosis ( ≥50% ) without myocardial infarction based on angiography (CAG) underwent 99Tcm-MIBI static planar and gated SPECT imaging. The early (90 min after the intravenous injection) and delayed (4 h after the intravenous injection) washout rates of 99Tcm-MIBI and left ventricular ejection fraction (LVEF) of IHD patients and normal subjects were compared using t-test. Linear correlation analysis was performed between the early, delayed washout rates and LVEF measured by gated SPECT. Results Statistically significant lower early washout rate of 99Tcm-MIBI was observed in IHD group than control group: (13.44 ± 2.87 )%vs ( 17.32 ± 4.92) %, t = 2.384, P < 0.05, but higher delayed washout rate of 99Tcm-MIBI was observed in IHD group than control group: (19.24 ±4.71)% vs (15.23 ±3.81)%, t= -2.246, P<0.05. LVEF in IHD group was significantly lower than that in control group: (55.71 ±7.97)% vs (67.75 ±5.43)%, t =-4.418, P <0.01. There were no correlations between the early/delayed washout rates and LVEF, respectively in IHD patients (r = -0.212, P > 0.05; r =0.352, P > 0.05, respectively). Conclusion 99Tcm-MIBI washout rate may reflect myocardial cell impairment due to IHD.

2.
Chinese Journal of Nuclear Medicine ; (6): 419-423, 2010.
Article in Chinese | WPRIM | ID: wpr-642241

ABSTRACT

Objective To explore an algorithm to define the threshold value for tumor contouring on 18F-fluorodexyglucose (FDG) PET imaging. Methods A National Electrical Manufacturing Association (NEMA)NU 2 1994 PET phantom with 5 spheres of different diameters were filled with 18F-FDG. Seven different sphere-to-background ratios were obtained and the phantom was scanned by Discovery LS 4. For each sphere-to-background ratio, the maximum standardized uptake value ( SUVmax ) of each sphere, the SUV of the border of each sphere ( SUVborder ), the mean SUV of a 1 cm region of background (SUVbg) and the diameter (D) of each sphere were measured. SPSS 13.0 software was used for curve fitting and regression analysis to obtain the threshold algorithm. The calculated thresholds were applied to delineate 29 pathologically confirmed lung cancer lesions on PET images and the obtained volumes were compared with the volumes contoured on CT images in lung window. Results The algorithm for defining contour threshold is TH% = 33.1% + 46.8% SUVbg/SUVmax + 13.9%/D ( r = 0.994) by phantom studies. For 29 lung cancer lesions, the average gross tumor volumes ( GTV ) delineated on PET and CT are ( 7.36 ± 1.62 ) ml and (8.31 ±2.05) ml, respectively (t = -1.26, P>0.05). Conclusion The proposed threshold algorithm for tumor contouring on PET image could provide comparable GTV with CT.

SELECTION OF CITATIONS
SEARCH DETAIL