Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Braz. oral res ; 21(3): 253-258, 2007. tab
Article in English | LILACS | ID: lil-458599

ABSTRACT

There are situations in which intraradicular retainers have to be removed and replaced. The objective of this research was to evaluate the apical seal after the removal of a custom cast post and core with a carbide bur or with an ultrasound apparatus. Twenty five roots of extracted human incisors were used. They were endodontically treated and prepared to receive the posts. The posts and cores were cast with 2 types of dental alloys, CuAlZn and PdAg, and were cemented with zinc phosphate cement. After 24 hours, they were removed using the two above mentioned techniques. Then, the roots had their external surface made impermeable by two layers of cyanoacrylate adhesive, leaving only the cervical area for dye penetration. The teeth were immersed in rhodamine for 24 hours. They were then cut and observed under an optical microscope and analyzed with appropriate software (Imagelab). The results were submitted to ANOVA, and they evidenced that, regarding the alloy factor, PdAg posts presented a larger mean infiltration value (2.23 ± 0.48 mm) as compared to the posts made of CuAlZn (1.39 ± 0.48 mm) (p = 0.025). Regarding the technique factor, there was no significant difference (p = 0.9) between the removal of the intraradicular retainer using ultrasound (1.99 ± 0.62 mm) or using a rotating cutting instrument (1.62 ± 0.62 mm). Under these experimental conditions, it was possible to conclude that the degree of apical leakage was directly related to the alloy type, and it was present in both techniques used.


Há situações que exigem a remoção ou substituição de retentores intra-radiculares. O objetivo deste trabalho foi avaliar o selamento apical do material obturador após a remoção de pino intra-radicular metálico fundido com instrumento cortante rotatório ou com aparelho de ultra-som. Utilizaram-se 25 raízes de incisivos humanos extraídos, que foram endodonticamente tratadas e preparadas para receberem os pinos. Os retentores intra-radiculares foram fundidos com 2 tipos de ligas odontológicas, CuAlZn e PdAg, e foram cimentados com cimento de fosfato de zinco. Após 24 horas, foram removidos com as 2 técnicas citadas. Em seguida, os dentes foram impermeabilizados com cianoacrilato de etila, permitindo a entrada do corante apenas por via cervical. Os dentes foram imersos em rodamina por 24 horas, depois foram clivados e observados em microscópio óptico de luz e analisados em "software" próprio (Imagelab). Os resultados foram submetidos à análise de variância e mostraram que, para o fator liga, os pinos de PdAg geraram uma média de infiltração maior (2,23 ± 0,48 mm) do que os pinos de CuAlZn (1,39 ± 0,48 mm), com p = 0,025; para o fator técnica, não houve diferença significante, com p = 0,9, entre a remoção com ultra-som (1,99 ± 0,62 mm) e a remoção com instrumento cortante rotatório (1,62 ± 0,62 mm). Nestas condições experimentais, foi possível concluir que o grau de infiltração apical está relacionado com o tipo de liga, e a infiltração esteve presente em ambas as técnicas utilizadas.


Subject(s)
Humans , Dental Instruments , Dental Alloys/chemistry , Dental Leakage/etiology , Device Removal/instrumentation , Post and Core Technique/instrumentation , Root Canal Preparation/standards , Analysis of Variance , Post and Core Technique/adverse effects , Root Canal Filling Materials/chemistry , Root Canal Therapy/standards , Tooth Fractures/etiology , Ultrasonics
2.
RBP Rev. bras. implantodont. protese implant ; 10(37): 78-82, jan.-mar. 2003. ilus
Article in Portuguese | LILACS, BBO | ID: lil-366054

ABSTRACT

A utilização de implantes para suportar sobredentaduras está comprovada por vários autores na literatura. Inúmeros sistemas de abutments estão disponíveis no mercado; a escolha depende de fatores que variam de acordo com o quadro clínico presente. A retenção e a estabilidade são requisitos fundamentais a qualquer sistema. Em alguns casos, a facilidade de inserção da prótese em posição pelo paciente pode-se tornar um fator determinante nesta escolha. A descrição e a utilização de um novo abutment, o sistema Locator, são relatadas neste trabalho.


Subject(s)
Humans , Male , Aged , Dental Prosthesis , Dental Implants
3.
Rev. odontol. Univ. Säo Paulo ; 12(3): 253-6, jul.-set. 1998. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-230109

ABSTRACT

Com a preocupaçäo de avaliar os efeitos danosos da transmissäo de calor aos tecidos periodontais, este trabalho teve como objetivo avaliar a temperatura gerada durante a remoçäo de pinos intra-radiculares com o uso de instrumentos cortantes rotatórios (ICR) em alta rotaçäo. Para se obter os registros da temperatura durante os desgastes, foram fixados fios termopares ao redor do terço médio e terço apical da raiz de incisivos centrais superiores extraídos, conectados a termômetros digitais. Através da análise de variância, verificou-se que houve diferença estatisticamente significante, 5 por cento, entre as regiöes medidas e as ligas utilizadas. Analisando as regiöes, observou-se, na regiäo mediana, amplitude de 9,1ºC, e, na regiäo apical, amplitude de 6,2ºC. A liga de CuAlZn (GOLDENT) alcançou média de amplitude maior, 10,3ºC, as ligas de CuAl (DURACAST), 6,3ºC, e a de PdAg (PORS-ON 4), 6,3ºC...


Subject(s)
Dental High-Speed Equipment , Hot Temperature , Dental Pins
SELECTION OF CITATIONS
SEARCH DETAIL