Journal of Forensic Medicine ; (6): 382-387, 2023.
Article in English | WPRIM | ID: wpr-1009369

ABSTRACT

OBJECTIVES@#To study the virtual reality-pattern visual evoked potential (VR-PVEP) P100 waveform characteristics of monocular visual impairment with different impaired degrees under simultaneous binocular perception and monocular stimulations.@*METHODS@#A total of 55 young volunteers with normal vision (using decimal recording method, far vision ≥0.8 and near vision ≥0.5) were selected to simulate three groups of monocular refractive visual impairment by interpolation method. The sum of near and far vision ≤0.2 was Group A, the severe visual impairment group; the sum of near and far vision <0.8 was Group B, the moderate visual impairment group; and the sum of near and far vision ≥0.8 was Group C, the mild visual impairment group. The volunteers' binocular normal visions were set as the control group. The VR-PVEP P100 peak times measured by simultaneous binocular perception and monocular stimulation were compared at four spatial frequencies 16×16, 24×24, 32×32 and 64×64.@*RESULTS@#In Group A, the differences between P100 peak times of simulant visual impairment eyes and simultaneous binocular perception at 24×24, 32×32 and 64×64 spatial frequencies were statistically significant (P<0.05); and the P100 peak time of normal vision eyes at 64×64 spatial frequency was significantly different from the simulant visual impairment eyes (P<0.05). In Group B, the differences between P100 peak times of simulant visual impairment eyes and simultaneous binocular perception at 16×16, 24×24 and 64×64 spatial frequencies were statistically significant (P<0.05); and the P100 peak time of normal vision eyes at 64×64 spatial frequency was significantly different from the simulant visual impairment eyes (P<0.05). In Group C, there was no significant difference between P100 peak times of simulant visual impairment eyes and simultaneous binocular perception at all spatial frequencies (P>0.05). There was no significant difference in the P100 peak times measured at all spatial frequencies between simulant visual impairment eyes and simultaneous binocular perception in the control group (P>0.05).@*CONCLUSIONS@#VR-PVEP can be used for visual acuity evaluation of patients with severe and moderate monocular visual impairment, which can reflect the visual impairment degree caused by ametropia. VR-PVEP has application value in the objective evaluation of visual function and forensic clinical identification.


Subject(s)
Humans , Evoked Potentials, Visual , Vision, Ocular , Vision, Binocular/physiology , Vision Disorders/diagnosis , Virtual Reality
2.
Journal of Forensic Medicine ; (6): 762-766, 2020.
Article in Chinese | WPRIM | ID: wpr-985172

ABSTRACT

Objective To explore a kind of visual evoked potential test equipment and method that is more suitable for the application of forensic clinical visual acuity evaluation. Methods Thirty-four volunteers (68 eyes) were selected, including 15 males and 19 females, aged between 20 and 40 years. Test lenses were placed before the tested eyes of volunteers to induce refractive myopia with insert method, and the diopter lenses were adjusted so that the visual acuity level of one eye of volunteers was above 0.8, and the visual acuity of the other eye was at moderate damage level (<0.3 and ≥0.1). The tests were carried out under the binocular simultaneous asynchronous stimulation mode (hereinafter referred to as "binocular mode") and monocular separate stimulation mode (hereinafter referred to as "monocular mode") of virtual reality-pattern visual evoked potential (VR-PVEP), and the amplitude of PVEP of volunteers under the two modes was compared at four spatial frequencies of 8×8, 16×16, 24×24 and 32×32. Results The differences in the amplitude of P100 wave between monocular and binocular modes at 8×8 spatial frequency had no statistical significance and the differences in amplitude of P100 wave between monocular and binocular modes at 16×16, 24×24, and 32×32 spatial frequencies had statistical significance (P<0.05). The amplitude of the same eye in monocular mode was higher than that in binocular mode. Through correlation analysis, it was found that the amplitude of P100 wave in monocular mode was moderately correlated with amplitude of P100 wave in binocular mode. Conclusion In forensic identification practice, VR-PVEP is helpful for overcoming the disturbance of poor fixation, and to increase the reliability of PVEP evaluation results. It can greatly shorten the detection time of PVEP and improve work efficiency.


Subject(s)
Adult , Female , Humans , Male , Young Adult , Evoked Potentials, Visual , Eye , Reproducibility of Results , Virtual Reality , Visual Acuity