Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiology ; (12): 1029-1035, 2021.
Article in Chinese | WPRIM | ID: wpr-910264

ABSTRACT

Objective:To investigate the stability and feasibility of improved silent MRA technique based on hybrid-arterial spin labeling(ASL) for imaging intracranial arterial stenosis.Methods:From September 2019 to May 2020, totally 35 patients with suspected intracranial vascular stenosis in Department of Neurology of Northern Jiangsu People′s Hospital were enrolled in this study. Silent MRA and improved silent MRA based on hybrid-ASL technique were performed respectively. The acquisition noise (noise measurement and subjective score) of two kinds of MRA examination were evaluated respectively. Two neuroradiologists performed image quality scoring and signal-to-noise ratio (SNR) measurement of intracranial arteries (including internal carotid artery, vertebrobasilar artery, anterior cerebral artery, middle cerebral artery, and posterior cerebral artery) in the two kinds of MRA images using a double-blind, completely randomized method. Independent sample t-test was used to compare the image quality and SNR of two kinds of MRA images in each segment. Two experts assessed the degree of stenosis at the site of confirmed intracranial artery stenosis. Kappa test was used to assess interobserver and intermodel agreement. Results:There was no significant difference in acquisition noise between improved silent MRA and silent MRA ( P>0.05). In all five segments measured, the image quality scores of internal carotid artery [(4.40±0.49)scores], anterior cerebral artery[(4.30±0.33)scores] and middle cerebral artery [(4.46±0.34)scores] in improved silent MRA were higher than those in silent MRA images [(4.02±0.43)scores, (4.02±0.31)scores, (4.02±0.31)scores; t=2.825, 2.877, 1.683, all P<0.05)]. The SNR of internal carotid artery (9.11±1.23) and middle cerebral artery (8.77±1.87) in improved silent MRA images was higher than that in silent MRA images (7.83±1.33, 8.06±2.67, respectively; t=11.154, 3.268, both P<0.05). A total of 24 patients (38 lesions) with intracranial vascular stenosis were diagnosed by CTA. Improved silent MRA (Kappa=0.89, 95%CI 0.82-0.95) and silent MRA (Kappa=0.85, 95%CI 0.77-0.92) were highly consistent among observers in evaluating the degree of cerebrovascular stenosis.The results of improved silent MRA were highly consistent with those of CTA (Kappa=0.92, 95%CI 0.87-0.98), and those of silent MRA were highly consistent with those of CTA (Kappa=0.85, 95%CI 0.77-0.92). Conclusions:The improved silent MRA is feasible to improve the imaging quality and signal uniformity through efficient marking based on keeping the low noise features. In the diagnosis of intracranial stenosis and occlusive disease, the stability of improved silent MRA imaging improves the diagnostic efficiency of stenosis to a certain extent.

2.
China Pharmacy ; (12): 4827-4830, 2015.
Article in Chinese | WPRIM | ID: wpr-501199

ABSTRACT

OBJECTIVE:To prepare mesopocous molecular sieve SBA-15 surface molecularly imprinted polymer (SBA-15@MIP),and analyze the application of SBA-15@MIP in the determination of active micro-component. METHODS:Using baica-lein as the template molecule,acrylamide(AM)as the function monomer,tetrahydrofuran/ethanol(3∶2,V/V)as the polymeriza-tion solvent,ethylene glycol dimethacrylate(EGDMA)as the cross-linker,and 2,2-azobisisobutyronitrile(AIBN)as the initiator, SBA-15@MIP was synthesized on the surface of mesopocous molecular sieve SBA-15. The surface morphology and structure of the obtained polymer were characterized by TEM and FT-IR. Finally,the imprinted polymer was used as an adsorbent for solid-phase extraction (SPE) to detect baicalein in plasma samples by HPLC. RESULTS:It revealed that the well-ordered one-dimensional pore structure of SBA-15 was still preserved in the successful synthesized SBA-15@MIP,and baicalein molecule was imprinted suc-cessfully. The limit of detection(LOD)and limit of quantification(LOQ)for baicalein in plasma were 3.5 ng/ml and 11.6 ng/ml, respectively;the average recovery was 94.4%(RSD=2.9%). CONCLUSIONS:SBA-15@MIP is prepared successfully,and can be applied for the determination of active micro-component.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 294-296, 2012.
Article in Chinese | WPRIM | ID: wpr-427030

ABSTRACT

Objective To study the relationship between parameter settings in the intensity-modulated radiation therapy (IMRT) planning in order to explore the effect of parameters on absolute dose verification.Methods Forty-three esophageal carcinoma cases were optimized with Pinnacle 7.6c by experienced physicist using appropriate optimization parameters and dose constraints with a number of iterations to meet the clinical acceptance criteria.The plans were copied to water-phantem,0.13 cc ion Farmer chamber and DOSE1 dosimeter was used to measure the absolute dose.The statistical data of the parameters of beams for the 43 cases were collected,and the relationships among them were analyzed.The statistical data of the dosimetry error were collected,and comparative analysis was made for the relation between the parameters of beams and ion chamber absolute dose verification results.Results The parameters of beams were correlated among each other.Obvious affiliation existed between the dose accuracy and parameter settings.When the beam segment number of IMRT plan was more than 80,the dose deviation would be greater than 3% ; however,if the beam segment number was less than 80,the dose deviation was smaller than 3%.When the beam segment number was more than 100,part of the dose deviation of this plan was greater than 4%.On the contrary,if the beam segment number was less than 100,the dose deviation was smaller than 4% definitely.Conclusions In order to decrease the absolute dose verification error,less beam angles and less beam segments are needed and the beam segment number should be controlled within the range of 80.

4.
Chinese Traditional Patent Medicine ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-573168

ABSTRACT

AIM: To observe the supplementation action of the crude and processed Epimedium Sapittatum Maxim. METHODS: The effects of different extracts of Epimedium Sagittatum Maxim. on the castrated mice were observed. RESULTS: The aqueous and alcohol extracts of the crude and processed Epimedium Sagittatum maxim. showed same marked inhibition on atrophy of castrated mice. CONCLUSION: The crude and processed Epimedium Sagittatum maxim. both have the supplementation action and show no marked difference in action.

SELECTION OF CITATIONS
SEARCH DETAIL