Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1482-1487, 2021.
Article in Chinese | WPRIM | ID: wpr-906600

ABSTRACT

@#Objective    To investigate the application of computational fluid dynamics (CFD) in hemodynamic evaluation of aortic root reconstruction. Methods    The clinical data of 1 patient with severe aortic valve stenosis was analyzed. Enhanced CT images were used as the original data, and professional software was used to reconstruct the three-dimensional (3D) model and fluid mechanics simulation of the aorta (including preoperative, postoperative and ideal conditions). Results    The 3D reconstruction model could directly present the distribution of valve calcification and the dilatation of the ascending aorta. The remodeled sinotubular junction and sinus structure were observed in the model under postoperative and ideal conditions. The improvement of ascending aorta dilatation was evaluated statistically by the diameter distribution before and after surgery. CFD simulation showed that the area of high flow velocity, pressure intensity and wall shear stress before surgery were consistent with the expansion area of the ascending aorta, and the restricted blood flow acceleration was observed at the angle between the arch and the descending aorta. In the ideal condition, the streamline of blood at the descending aorta was more stable and flat compared with preoperative or postoperative conditions, and there was no obvious abnormal high pressure and high wall shear stress area in the ascending aorta. The cardiopulmonary bypass time was 106 min, of which the aortic cross-clamp time was 60 min. The cardiac echocardiography indicated that the aortic valve worked well, and the peak systolic blood velocity was 1.7 m/s. The length of hospital stay after surgery was 12 d, including 2 d in ICU. The ventilator use time was 11.6 h. The patient did not have any remarkable discomfort during the 1-year follow-up. Conclusion    CFD can be used to evaluate anatomic and hemodynamic abnormalities before aortic root reconstruction surgery. Postoperative reconstruction simulation can be performed again to evaluate the surgical effect, and meanwhile, virtual improvement can be tried for the unresolved problems to accumulate diagnosis and treatment experience, so as to provide patients with more accurate and personalized diagnosis and treatment procedure.

2.
Chinese Journal of Cardiology ; (12): 852-856, 2017.
Article in Chinese | WPRIM | ID: wpr-809384

ABSTRACT

Objective@#To investigate the association between D-dimer levels and clinical events in patients with mechanical heart valve replacement under oral anticoagulation therapy.@*Methods@#This prospective study included 640 consecutive patients underwent mechanical heart valve replacement in Wuhan Asia Heart Hospital between January 2013 and June 2014.Patients were assigned to abnormal D-dimer group (D-dimer level>cut off value, n=88) and normal D-dimer group (D-dimer level≤cut off value, n=552) according to D-dimer levels measured at 3 months after the initiation of oral anticoagulation therapy.All patients were followed up for 24 months or until the observation of the end points, which included thrombotic events, bleeding events and all-cause deaths.The anticoagulation therapy was monitored once per 1-2 months by the international normalized ratio (INR), and the target value was 1.8-3.0.@*Results@#During a follow-up period of 24 months, rates of total clinical events (19.30%(17/88) vs. 5.8%(32/552), P<0.01), thrombotic events (11.4%(10/88) vs. 2.3%(13/552), P<0.01), and all-cause deaths (8.0%(7/88) vs. 2.0%(11/552), P<0.01) were all significantly higher in abnormal D-dimer group than in normal D-dimer group.There were no significant difference in bleeding events between the two groups (2.3%(2/88) vs. 3.1%(17/552), P=0.77). Multivariate Cox regression analysis showed that high D-dimer level was an independent risk factor of total clinical events (HR=3.86, 95%CI 1.92-7.76, P<0.01), thrombotic events(HR=5.29, 95%CI 2.12-13.10, P<0.01), and all-cause deaths(HR=5.32, 95%CI 1.71-16.60, P<0.01), but which was not correlated with bleeding events(HR=1.36, 95%CI 0.27-6.84, P=0.71).@*Conclusion@#Elevated D-dimer levels are linked with clinical events in patients with mechanical heart valve replacement under oral anticoagulation therapy.

SELECTION OF CITATIONS
SEARCH DETAIL