Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiation Oncology ; (6): 260-265, 2016.
Article in Chinese | WPRIM | ID: wpr-488228

ABSTRACT

Objective To test the accuracy and reliability of Axesse accelerator for volumetric modulated arc therapy (VMAT).Methods The accuracy and reliability of Axesse accelerator for VMAT were tested in a stepwise manner, from the simple to the complex and from the part to the whole.For the parts of the system, the stability of dosimetric output and the position accuracy of multi-leaf collimator (MLC) were tested.For the process of the system, the variable VMAT dose rates and gantry speed modulation, the MLC speed and dose rate modulation, and dosimetric verification in patients were tested.Results Compared with fixed gantry irradiation, the variation in dosimetric output was below 1.0% for rotary irradiation including the slide rotary irradiation of the dynamic MLC.The MLC position error of 0.5 mm was visible using the electronic portal imaging system of Axesse, iViewGT 3.40.The MLC position accuracy was within 1 mm for fixed gantry irradiation and rotary irradiation.In the range of the dose rate applied in clinical practice, the testing results of variable VMAT dose rates and gantry speeds as well as variable dose rates and MLC speeds showed that the variation between different strip-field beam intensities was below 2.0%.Using a gamma criterion of 3 mm/3%, the pass rates in dosimetric verification of patients with cervical cancer, prostate cancer, and breast cancer were 96.52%, 95.72%, and 98.83%, respectively.Conclusions The Axesse system can precisely control MLC motion, variable dose rates, and gantry speeds in VMAT.The Axesse system is accurate and reliable for VMAT.

2.
Chinese Journal of Radiation Oncology ; (6): 190-193, 2016.
Article in Chinese | WPRIM | ID: wpr-487549

ABSTRACT

Based on a review of currently published 40 papers ( 20 published in recent 5 years, 20 published in recent 10 years) on gold nanoparticles for cancer radiotherapy, the general characteristics, theoretical studies, in vitro experiment, in vivo experiment,and the clinical prospects of targeted radiotherapy with gold nanoparticles were reviewed. Three key aspects guarantee further investigation for the full understanding of the radiosensitization effect of gold nanoparticles:the cellular localization and tissue distribution of nanoparticles and influential factors;the micro dose enhancement effect of gold nanoparticles, and the molecular biological mechanism. More cross disciplinary collaboration, research, development and translation are needed before gold nanoparticles are put into clinical trials.

3.
International Journal of Biomedical Engineering ; (6): 230-233,237,后插4, 2012.
Article in Chinese | WPRIM | ID: wpr-555651

ABSTRACT

Multimodality medical image registration has become increasingly popular in the field of image processing,and it has significant meaning for the clinical diagnosis and treatment.In this article,the process of image registration is described,and a full review and comparison of some typical medical image registration methods are given according to the features of the images including internal and external characteristics.

SELECTION OF CITATIONS
SEARCH DETAIL