Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Acta bioquím. clín. latinoam ; 38(2): 159-163, mar.-jun. 2004. tab
Article in Spanish | LILACS | ID: lil-632974

ABSTRACT

El Trasudado Mucoso Oral (TMO) es un fluido biológico que puede obtenerse mediante una almohadilla absorbente colocada entre la encía y la mejilla inferior y que contiene 20% de IgG, 40% de IgA y 10% de IgM en relación al suero. El objetivo del trabajo fue analizar la confiabilidad del TMO como muestra biológica para la detección de anticuerpos en Chagas y Toxoplasmosis. Sueros de pacientes ambulatorios, embarazadas y voluntarios sanos fueron estudiados para Chagas y Toxoplasmosis empleando Inmunofluorescencia, ELISA y Hemaglutinación. Las muestras de TMO fueron estudiadas por ELISA y los resultados comparados con los métodos de referencia para determinar sensibilidad (S), especificidad (E), valor predictivo positivo (VPP) y valor predictivo negativo (VPN). En Chagas, la sensibilidad osciló entre 91% y 100% con tres diferentes equipos ensayados, mientras la especificidad varió entre 90 y 100%, el VPP entre 95% y 96% y el VPN entre 97% y 99%. En Toxoplasmosis no se detectaron resultados falsos positivos (S 95%, E 100%, VPP 100% y VPN 98%). Estos resultados sugieren que el TMO puede ser un fluido biológico alternativo adecuado para estudios inmunoepidemiológicos y también servir como screening en el diagnóstico y prevención de la transmisión vertical de enfermedades infecciosas.


Oral mucosal transudate (OMT) is a biological fluid that can be obtained by an absorbent pad placed between lower cheek and gum, and contains20% IgG, 40% IgA and 10% IgM comparing with serum. The aim of this work was to analyse the performance of OMT as biological material to detect antibodies in Chagas' disease and Toxoplasmosis. Sera of ambulatory patients, pregnant women and healthyvolunteers were tested for Chagas and Toxoplasmosis employingImmunofluorescence, ELISA andHemagglutination.OMT of the same patients were assayed by ELISA, and the results compared to determinate sensibility, specificity and predictive value. In Chagas serology, three different commercial kits were assayed. The sensibility ranged from 91 to 100%,specificitybetween 90 and 100%. The predictive values oscillate between 95% and 99%. The studies in Toxoplasmosis did not shown false positive results. The sensibility was 95%, specificity 100% and the predictive values between 98% and100%. Sera from neonates born from Toxoplasmosis infected mothers were also studied, and the results were in agreement with reference tests. These results suggest that OMT could be a suitable alternative biological fluid in immunoepidemio-logical surveys, and also as screening test in the diagnosis and prevention of materno-fetal transmission of infectious diseases.


Subject(s)
Immunologic Tests , Seroepidemiologic Studies , Toxoplasmosis , Chagas Disease , Allergy and Immunology , Antibodies
SELECTION OF CITATIONS
SEARCH DETAIL