Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
China Journal of Chinese Materia Medica ; (24): 250-256, 2016.
Article in Chinese | WPRIM | ID: wpr-304863

ABSTRACT

A quick HPLC-ESI-MS/MS method was established for simultaneous determination of four major diterpenoids in Rabdosia japonica var.glaucocalyx, including glaucocalyxin A, oridonin, hebeirubesensin and enmenol. Analysis was performed on an Agilent ZORBAX SB-C18(4.6 mm×250 mm, 5 μm ) column eluted in a gradient program with methanol and water. The flow rate was 0.8 mL•min⁻¹. Multiple reaction monitoring (MRM) scanning mode was performed in negative ion switching mode to apply for the quantitative determination. The calibration curves for the above four compounds were linear in corresponding injection amount. The average recoveries of the compounds ranged from 92.40% to 105.9%, with RSDs of 1.7%-6.5%. The method is simple, rapid, accurate with good repeatability, which can provide a reference for overcalling evaluation the quality of R. japonica var.glaucocalyx. The result of cluster analysis- showed that the quality of R. japonica glaucocalyx var. greatly varied between areas and parts.

2.
China Journal of Chinese Materia Medica ; (24): 4884-4889, 2015.
Article in Chinese | WPRIM | ID: wpr-236027

ABSTRACT

A quick HPLC-ESI-MS/MS method was established for simultaneous determination of three chemical compositions in Usnea, including usnic acid, diffractaic acid, and ramalic acid. The separation was performed on a chromatographic column of Agilent ZORBAX SB-C, (4.6 mm x 250 mm, 5 µm), and the mobile phase was methanol (0.05% formic acid)-0.05% formic acid solution (4 mmol ammonium acetate), with an isocratic elution at a flow rate of 0.8 ml · min⁻¹. Multiple reaction monitoring scanning mode (MRM) was performed combined with the ion switching technology in positive and negative ion switching mode to apply for the quantitative determination. The calibration curves for the above three compounds were linear in corresponding injection amount. Their average recoveries were 95.0%-105.1%, with RSDs of 1.1%-5.2%. The method was simple, rapid, accurate with high repeatability, which could provide a reference for overcalling evaluation the quality of Usnea.


Subject(s)
Chromatography, High Pressure Liquid , Methods , Hydroxybenzoates , Spectrometry, Mass, Electrospray Ionization , Methods , Tandem Mass Spectrometry , Methods , Usnea , Chemistry
SELECTION OF CITATIONS
SEARCH DETAIL