Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
International Journal of Biomedical Engineering ; (6): 196-204, 2023.
Article in Chinese | WPRIM | ID: wpr-989339

ABSTRACT

Objective:To simulate the spot characteristics of light emitting diode (LED) array light sources used in non-invasive phototherapy at different distances and to provide reference for the formulation of clinical non-invasive phototherapy treatment schemes.Methods:The ray tracing module in Comsol software was used to simulate the spot characteristics of LED light sources with different power and arrays at different distances, and the fitting curve was analyzed. The model was verified by the actual LED spot measurement, and the feasibility of the treatment scheme was verified by the mouse back wound model.Results:Under the irradiation of 2×2 LED light source array, with the increase of the vertical distance from the light source, the area of the effective area and the treatment area gradually increased, the power density value in the area gradually decreased, and the uniformity gradually increased. These changes showed a linear or binomial correlation with the vertical distance. The model was improved based on the actual LED light spot, and the new model consisted of an array of 18 LEDs as the light source, and the treatment area showed better uniformity and power density values. The simulated optical parameters were used to treat mice’s wounds with light, and the results showed that light treatment could promote wound healing.Conclusions:The established medical LED array light source spot characteristics simulation can provide a reference for the development of clinical non-invasive phototherapy protocols, thus helping the clinic select the appropriate LED power and array distribution according to the treatment needs and also providing a basis for the development of medical LED array light sources.

2.
Journal of Regional Anatomy and Operative Surgery ; (6): 715-719, 2016.
Article in Chinese | WPRIM | ID: wpr-502971

ABSTRACT

Objective To study the anatomic data of the first metatarsal dorsal artery and to provide anatomical basis for clinical tissue transplantation based on the first metatarsal dorsal artery.Methods The 16 adult cadaver specimens with 32 feet were dissected and meas-ured by vernier caliper.Then the anatomic data of the first metatarsal dorsal artery were analyzed.Results Through the examinations of 32 feet sample,the first metatarsal dorsal artery were classified into 5 types.Type Ⅰ:the first metatarsal dorsal artery runs at the surface of the first dorsal interosseous muscle (13 sides,40.6%).Type Ⅱ:the first metatarsal dorsal artery runs in the interior of the first dorsal interosse-ous muscle (11sides,34.4%).Type Ⅲ:the first metatarsal dorsal artery runs underneath the first dorsal interosseous muscle (6 sides, 18.8%).Type Ⅳ:the first metatarsal dorsal artery is slender (1 side,3.1%).TypeⅤ:the first metatarsal dorsal artery is absent (1 side, 3.1%).Distance relationship was measured between the first metatarsal bone and the first metatarsal dorsal artery:the vertical distance be-tween the origin of the posterior branch of the first metatarsal dorsal artery and base of the first metatarsal bone was (2.4 ±0.3)mm,the ver-tical distance between the origin of the posterior branch of the first metatarsal dorsal artery and head of the first metatarsal bone was (10.1 ±1.0)mm;the vertical distance between the origin of the anterior branch of the first metatarsal dorsal artery and the first metatarso-phalangeal joint was (7.6 ±2.7)mm.Conclusion The first metatarsal dorsal artery has clinical reference significance for the hands and feet’s trauma and skin flap transplantation such as thumb reconstruction.

SELECTION OF CITATIONS
SEARCH DETAIL