Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Health ; (6): 240-244, 2023.
Article in Chinese | WPRIM | ID: wpr-978422

ABSTRACT

Objective To analyze the problems and solutions in the diagnosis of a patient with occupational radiogenic neoplasms. Methods The dose conversion method was selected in dose estimation. Personal dose equivalent, skin absorbed dose, and reported detection data were converted into red bone marrow absorbed dose. The upper 95% confidence limit of the probability of causation (PC 95%) was calculated. Results The PC 95% of cancer due to radiation in the worker was 66.38%, which suggested occupational radiogenic neoplasms. Personal dose data were missing in dose estimation. The current dose estimation standard lacked bedside radiography and CT operation type, and the dose conversion formula was not perfect. Conclusion In the judgment of occupational radiogenic neoplasms, the estimated dose showed uncertainty. There is an urgent need to formulate and promulgate dose estimation standards that are operational and in line with the current development of radiological diagnosis and treatment technology and equipment.

2.
Chinese Journal of Schistosomiasis Control ; (6): 92-93,96, 2016.
Article in Chinese | WPRIM | ID: wpr-603921

ABSTRACT

Objective To understand the changes of positive rates of IHA detections of outpatients in schistosomiasis clinic. Results The data of IHA detections of outpatients in schistosomiasis clinic in Hubei Provincial Center for Disease Control and Prevention were collected and analyzed statistically from 2005 to 2014. Results A total of 7 113 outpatients were detected by IHA test,and 547 of them were positives with a positive rate of 7.69%. The positive rate of IHA test was on an upward slope be?fore 2008,and the rate reached 14.85% in 2008,which was significantly higher than that in 2005(5.81%)( χ2 = 47.40,P<0.01),then it was on a declined stage after 2008,and the positive rate decreased to 3.76 in 2014,which was significantly lower than that in 2008( χ2 = 12.29,P<0.01). The positive rate of outpatients in the 10~<30 years age group was higher than those in other age groups(all P < 0.012 5),and the male positives were more than the female ones. Conclusions The schisto?somiasis endemic situation has been significantly decreased in Hubei Province. The male and people in 10~<30 age group are the high risk groups,so the targeted health education should be strengthened.

3.
International Journal of Laboratory Medicine ; (12): 2209-2210,2213, 2015.
Article in Chinese | WPRIM | ID: wpr-602322

ABSTRACT

Objective To grasp bilirubin in the quality control serum and calibration items in the same batch the variation law of the designed to ensure that the test quality and the use of reasonable quality control serum and calibration items ,control testing cost .Methods laboratories use The double level quality control serum and calibration items after dilution is divided into five groups ,with automatic biochemical analyzer test for 12 weeks and recorded results of TBIL ,DBIL .use SPSS 17 .0 to calculate the mean ,standard deviation ,coefficient of variation ,Normal distribution analysis and make the results trend line chart to observe any changes .Results RANDOX normal concentration quality control serum TBIL and DBIL values variation RCV% 26 .0% ,48 .2% , more than CLIA bilirubin projects allow 1/3 of the total error value(6 .67% ) .Normal distribution test ,P value was 0 .006 ,0 .012 , less than 0 .05 ,do not obey the normal distribution ,test results line chart is on the decline .LEADMAN high concentration quality control serum and bilirubin calibration items TBIL and DBIL variation RCV% 0 .05 ,obey the normal distribution ,test results no trend line chart .Conclusion Through the experiment observation to the quality control ser‐um and calibration items bilirubin in the variation law of 12 weeks .Experimenter can be used according to the actual situation to ad‐just ,not only to ensure the quality of the bilirubin test ,and to get the most out of the quality control serum and calibration items use efficiency ,reduce the test cost .

SELECTION OF CITATIONS
SEARCH DETAIL