ABSTRACT
OBJECTIVE@#To explore the feasibility of using the bidirectional local distance based medical similarity index (MSI) to evaluate automatic segmentation on medical images.@*METHODS@#Taking the intermediate risk clinical target volume for nasopharyngeal carcinoma manually segmented by an experience radiation oncologist as region of interest, using Atlas-based and deep-learning-based methods to obtain automatic segmentation respectively, and calculated multiple MSI and Dice similarity coefficient (DSC) between manual segmentation and automatic segmentation. Then the difference between MSI and DSC was comparatively analyzed.@*RESULTS@#DSC values for Atlas-based and deep-learning-based automatic segmentation were 0.73 and 0.84 respectively. MSI values for them varied between 0.29~0.78 and 0.44~0.91 under different inside-outside-level.@*CONCLUSIONS@#It is feasible to use MSI to evaluate the results of automatic segmentation. By setting the penalty coefficient, it can reflect phenomena such as under-delineation and over-delineation, and improve the sensitivity of medical image contour similarity evaluation.
Subject(s)
Feasibility Studies , Radiotherapy Planning, Computer-AssistedABSTRACT
Compared with the previous automatic segmentation neural network for the target area which considered the target area as an independent area, a stacked neural network which uses the position and shape information of the organs around the target area to regulate the shape and position of the target area through the superposition of multiple networks and fusion of spatial position information to improve the segmentation accuracy on medical images was proposed in this paper. Taking the Graves' ophthalmopathy disease as an example, the left and right radiotherapy target areas were segmented by the stacked neural network based on the fully convolutional neural network. The volume Dice similarity coefficient (DSC) and bidirectional Hausdorff distance (HD) were calculated based on the target area manually drawn by the doctor. Compared with the full convolutional neural network, the stacked neural network segmentation results can increase the volume DSC on the left and right sides by 1.7% and 3.4% respectively, while the two-way HD on the left and right sides decrease by 0.6. The results show that the stacked neural network improves the degree of coincidence between the automatic segmentation result and the doctor's delineation of the target area, while reducing the segmentation error of small areas. The stacked neural network can effectively improve the accuracy of the automatic delineation of the radiotherapy target area of Graves' ophthalmopathy.