Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Radiol. bras ; 41(6): 361-365, nov.-dez. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-507115

ABSTRACT

OBJETIVO: Avaliar a acurácia da colangiografia por ressonância magnética no estudo da anatomia biliar de doadores de fígado em correlação com achados operatórios. MATERIAIS E MÉTODOS: Estudo retrospectivo de 50 doadores submetidos a transplante hepático intervivos no Hospital de Clínicas da Universidade Federal do Paraná, Curitiba, PR. As colangiografias foram analisadas e os resultados dos exames foram comparados com os achados intra-operatórios. Apenas alterações anatômicas que promoveram mudança de estratégia cirúrgica, não-evidenciadas previamente pela colangiografia por ressonância magnética, foram consideradas como discordantes. RESULTADOS: Foram encontradas variações pela colangiografia por ressonância magnética em 7 doadores e em 14 durante a cirurgia. Do total de pacientes, 41 resultados foram concordantes e 9 foram discordantes. A sensibilidade, a especificidade, o valor preditivo positivo, o valor preditivo negativo e a acurácia da colangiografia por ressonância magnética foram, respectivamente, de 43%, 97%, 86%, 81% e 81,6%. CONCLUSÃO: Conclui-se que a ressonância magnética é um método de imagem seguro e não-invasivo para avaliação pré-operatória das vias biliares de doadores e que algumas anomalias não são detectadas pela colangiografia por ressonância magnética.


OBJECTIVE: The present study was aimed at evaluating the accuracy of magnetic resonance cholangiography in the assessment of the biliary anatomy in living liver donors in correlation with surgical findings. MATERIALS AND METHODS: Fifty living liver donors were retrospectively evaluated at Hospital de Clínicas da Universidade Federal do Paraná, Curitiba, PR, Brazil. Cholangiographic images were analyzed and results were compared with intraoperative findings. Only anatomical alterations that affected the surgical strategy and had not been previously observed at magnetic resonance cholangiography were considered as being in disagreement. RESULTS: Anatomical variations were found in 7 donors at magnetic resonance cholangiography, and in 14 during surgery. Agreement between imaging and surgical findings was observed in 41 of the 50 patients, and disagreement in 9. Magnetic resonance cholangiography sensitivity, specificity, positive and negative predictive values, and accuracy were respectively 43%, 97%, 86%, 81% and 81.6%. CONCLUSION: Magnetic resonance imaging is a safe and noninvase method for preoperative evaluation of the biliary tract in living liver donors. However some anatomical abnormalities are not detected by magnetic resonance cholangiography.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Diagnostic Imaging , Magnetic Resonance Spectroscopy , Liver/anatomy & histology , Living Donors , Magnetic Resonance Imaging , Liver Transplantation/methods , Brazil , Diagnostic Imaging/trends , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL