Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 107-114, 2011.
Article in Korean | WPRIM | ID: wpr-64852

ABSTRACT

PURPOSE: To assess the degree and clinical impact of location error of the dens on the X-axis during radiotherapy to brain and head and neck tumors. MATERIALS AND METHODS: Twenty-one patients with brain tumors or head and neck tumors who received three-dimensional conformal radiation therapy or intensity-modulated radiation therapy from January 2009 to June 2010 were included in this study. In comparison two-dimensional verification portal images with initial simulation images, location error of the nasal septum and the dens on the X-axis was measured. The effect of set-up errors of the dens was simulated in the planning system and analyzed with physical dose parameters. RESULTS: A total of 402 portal images were reviewed. The mean location error at the nasal septum was 0.16 mm and at the dens was 0.33 mm (absolute value). Location errors of more than 3 mm were recorded in 43 cases (10.7%) at the nasal septum, compared to 133 cases (33.1%) at the dens. There was no case with a location error more than 5 mm at the nasal septum, compared to 11 cases (2.7%) at the dens. In a dosimetric simulation, a location error more than 5 mm at the dens could induce a reduction in the clinical target volume 1 coverage (V95: 100%-->87.2%) and overdosing to a critical normal organ (Spinal cord V45: 12.6%). CONCLUSION: In both brain and head and neck radiotherapy, a relatively larger set-up error was detected at the dens than the nasal septum when using an electronic portal imaging device. Consideration of the location error of the dens is necessary at the time of the precise radiation beam delivery in two-dimensional verification systems.


Subject(s)
Humans , Brain , Brain Neoplasms , Electronics , Electrons , Head , Nasal Septum , Neck
2.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 194-200, 2009.
Article in Korean | WPRIM | ID: wpr-21054

ABSTRACT

PURPOSE: This aim of this study was to evaluate changes in gastric volume and organ position as a result of delayed gastric emptying after a subtotal gastrectomy performed as part of the treatment of stomach cancer. MATERIALS AND METHODS: The medical records of 32 patients who underwent concurrent chemoradiotherapy after a subtotal gastrectomy from March 2005 to December 2008 were reviewed. Of these, 5 patients that had more than 50 cc of residual gastric food detected at computed tomography (CT) simulation, were retrospectively enrolled in this study. Gastric volume and organ location was measured from CT images obtained before radiotherapy, twice weekly. In addition, authors evaluated the change of radiation dose distribution to planning the target volume and normal organ in a constant radiation therapy plan regardless of gastric volume variation. RESULTS: A variation in the gastric volume was observed during the radiotherapy period (64.2~340.8 cc; mean, 188.2 cc). According to the change in gastric volume, the location of the left kidney was shifted up to 0.7 - 2.2 cm (mean, 1.2 cm) in the z-axis. Under-dose to planning target volume (V43, 79.5+/-10.4%) and over-dose to left kidney (V20, 34.1+/-12.1%; Mean dose, 23.5+/-8.3 Gy) was expected, given that gastric volume change due to delayed gastric emptying wasn't taken into account. CONCLUSION: This study has shown that a great change in gastric volume and left kidney location may occur during the radiation therapy period following a subtotal gastrectomy, as a result of delayed gastric emptying. Detection of patients who experienced delayed gastric emptying and the application of gastric volume variation to radiation therapy planning will be very important.


Subject(s)
Humans , Chemoradiotherapy , Gastrectomy , Gastric Emptying , Kidney , Medical Records , Retrospective Studies , Stomach Neoplasms
SELECTION OF CITATIONS
SEARCH DETAIL