Journal of the Korean Radiological Society ; : 387-392, 2003.
Article in English | WPRIM | ID: wpr-124403

ABSTRACT

PURPOSE: To evaluate the physiologic background of aneurysms poorly visualized during 3D-TOF MRA, contrast-enhanced MRA (CEMRA) and DSA due to hemodynamic isolation. MATERIALS AND METHODS: Using handmade elastic silicon phantoms to represent terminal basilar tip aneurysms, 3D-TOF MRA, CEMRA and DSA were used to determine blood turnover. Aneurysmal neck size was 2 mm and 10 mm, and the use of a pulsatile pump also helped recreate human physiologic parameters. We compared the results with those of computational fluid dynamics. RESULTS: DSA images of the narrow-necked aneurysm showed that a small volume of contrast medium washed into it during the systolic phase. As the width of its neck increased, the turnover volume of fragments of contrast bolus also increased. At CEMRA, the broad-necked aneurysm was visualized as the main bolus of Gd-DT PA passed through it, and at delayed CEMRA, the narrow-necked aneurysm was visualized faintly after the passage of bolus Gd-DT PA. The results correlated closely with those of 3DTOF MRA and computational fluid dynamics. CONCLUSION: The visualization of intracranial aneurysms at 3D-TOF MRA, CEMRA and DSA was greatly dependent upon blood turnover, which varied according to aneurismal neck size. A narrow-necked aneurysm might be missed at 3D-TOF MRA, CEMRA and DSA due to hemodynamic isolation.


Subject(s)
Humans , Aneurysm , Angiography, Digital Subtraction , Hemodynamics , Hydrodynamics , Intracranial Aneurysm , Neck , Silicones
2.
Journal of the Korean Radiological Society ; : 545-552, 1997.
Article in Korean | WPRIM | ID: wpr-41933

ABSTRACT

PURPOSE: It has been suggested that an ulceration or hemorrhage within an atheroma on a stenotic carotid artery is a clinically important cause of transient ischemic attack(TIA). In previous studies, due to its inherent signal loss by static or turbulent flow, magnetic resonance angiography(MRA) proved to be an unreliable methed for the evaluation of subtle changes of ulceration. To improve the detectability of the ulceration within atheroma, avascular phantom was filled with gadolinium solution of various concentrations during various MR sequences. MATERIALS AND METHODS: Several vascular phantoms made of elastic silicon mimicking an ulcerated stenotic internal carotid artery(ICA) were constructed, and gadolinium solution of different concentrations (1:1000 and 1:200 of Gd-DTPA) and distilled water were introduced into the vascular phantoms using a computerized pulsatile pump. To evaluate maximum intensity projection(MIP), multiple planar reconstruction(MPR) and source images, axial and coronal images of MRA with 2D-TOF(time of flight) and 3D-TOF were reviewed. Each image of various sequences was compared with plain X-ray films of each phantom filled with barium. RESULTS: On all MR suquences, the images of the phantom of the normal carotid bifurcation were superior to the images of ulcerated and stenotic phantoms. MPR and MIP were the optimal image for detecting and defining ulceration and stenosis. Better quality images were obtained when a higher concentration of Gd-DTPA was used and when the 3D-TOF technique instead of the 2D-TOF technique was applied. CONCLUSION: This study reveals that a combination of higher concentration gadolinium with MPR and MIP on 3D-TOF technique could be optimal for the evaluation of ulceration and/or stenosis at the bifurcation of the carotid artery.


Subject(s)
Barium , Carotid Arteries , Carotid Artery, Internal , Constriction, Pathologic , Gadolinium , Gadolinium DTPA , Hemorrhage , Magnetic Resonance Angiography , Plaque, Atherosclerotic , Silicones , Ulcer , Water , X-Ray Film
3.
Journal of the Korean Radiological Society ; : 737-744, 1996.
Article in Korean | WPRIM | ID: wpr-67570

ABSTRACT

PURPOSE: The most important factor discrediting the reliability of MRAs is the overestimation of the degree of stenosis in the internal carotid artery(ICA). The purpose of this study is to evaluate the second aryhemodynamics and the cause(s) for the overestimation of the degree of variable stenotic phantoms of the carotidartery using steady-state flow on MRAs. MATERIALS AND METHODS: Using scrylic materials, normal and variable stenotic phantoms of the bifurcated carotid artery were constructed (40% and 65%). Flow patterns were evaluated with axial and coronal imaging of MRAs (2D-TOF and 3D-TOF) and DSAs of phantoms constructed from an automated closed-type circulatory system filled with 10% glucose solution. These findings were then compared with those obtained from CFD. RESULTS: 3D-TOF axial MRA of asymmetrically 40 percent stenotic phantom revealed 40 percent stenosis identical to the stenotic region of phantoms with continued poststenotic signal loss, whereas 3D-TOFzsial MRA of symmetrically 65 percent stenotic phantom showed markedly decreased signal intensity at the poststenotic segment resembling occlusion. Source image of 2D-TOF coronal MRA showed redistribution (from theinternal to external carotid artery side) of the central axis of inflow depending upon the degree of stenosis ofthe ICA ; this redistribution can be a cause of the decreased signal at the poststenotic segment, due to a reduced volume of flow through the stenotic segment. The general hemodynamics of the variable stenotic phantoms on MRA were identical to the hemodynamics on DSA and CFD. CONCLUSION: Although dephasing from turbulent flow and character of maximum intensity projection (MIP) were suggested as the main cause of the decreased poststenotic signal, our study indicated that a hemodynamically redistributed central axis of inflow and reduced flow volume through stenotic channel is one of the basic factors of the decreased signal intensity ot the poststenotic segmenton MRA.


Subject(s)
Axis, Cervical Vertebra , Carotid Arteries , Carotid Artery, External , Constriction, Pathologic , Glucose , Hemodynamics
4.
Journal of the Korean Radiological Society ; : 189-195, 1995.
Article in Korean | WPRIM | ID: wpr-168205

ABSTRACT

PURPOSE: A common finding of carotid artery on magnetic resonance angiograms(MRAs) is a signal dropout along the posterior wall of carotid bulb due to reverse flow. The purpose of this study is to evaluate variable flow patterns on bifurcated carotid arterial phantoms using steady-state flow. MATERIALS AND METHODS: We designed phantoms of a bifurcated carotid artery with acrylic materials. Flow patterns were evaluated with axial and coronal imaging of MRA(2D-TOF, 3D-TOF), color Doppler imaging, and computational fluid dynamics (CFD) within the phantoms constructed of an automated closed-type circulatory system filled with 4% sugar solution. These findings were compared with findings obtained from normal volunteers. RESULTS: Axial 3D-TOF MRA images exhibited closer resemblance to the contour of the inner wall of phantoms when compared to coronal 2D-TOF MRA imaging. However, 2D-TOF MRA showed good contrast difference of signal intensities between forward flow area and reverse flow area. Dark zones with reduced signal intensities due to reversed flow were separated from the outer wall of the internal and external carotid arteries by a thin layer of forward flow along the wall on the source slice image of MRA. The general hemodynamics of the phantoms on MRA were identical to hemodynamics on color Doppler imaging and CFD. The results obtained with the phantoms matched the findings on normal volunteers. CONCLUSION: Although representations of bifurcated carotid arterial phantoms on axial 3D-TOF MRA were excellent if ideally desinged, the zone of reversed flow could be a significant factor in creating distorted image when the zone of reversed flow contacted directly with curved or deformed arterial wall.


Subject(s)
Humans , Carotid Arteries , Carotid Artery, External , Healthy Volunteers , Hemodynamics , Hydrodynamics , Magnetic Resonance Angiography , Patient Dropouts