1.
Korean Journal of Occupational and Environmental Medicine ; : 499-508, 1996.
Article in Korean | WPRIM | ID: wpr-151457

ABSTRACT

In order to evaluate the mutagenic effects of extractable indoor air pollutants (organic matters), we measured the mutagenic activities by sensitive microsuspension Ames test using new tester strains (YG 1024 and YG 1029). And additionally to evaluate the mutagenic effects on vital cell, we examined the frequencies of micronucleus appearing in lymphocytes from dye handling workers and controls. This study was conducted from Jan. toMay, 1995. The extractable indoor air pollutants were collected by low volume air sampler in a general office room and 3 of dye handling factories. And the environment of general office room divided into 3 different groups according to the type of room heaters. To determine the frequencies of micronucleus appearing in lymphocytes, we sampled peripheral venous blood from 20 of dye handling workers and 20 of controls, and cultured, and then examined the lymphocytes. The results obtained were as follows: 1. The indirect mutagenic activities of extractable organic matters from suspended particulates colleced in a general office room were higher than the direct one. 2. The strain YG 1024 was the most sensitive, and the increasing order of test strainsthat showed higher number of revertant were YG 1024, YG 1029, TA 100, and TA 98. 3. In the general office room, the room using kerosene heater showed the highest mutagenecity, and the next was buthan gas heater, and non-heating room in order. 4. The mutagenic effects of suspended particulates in::dye handling factories on the strain YG 1024 was 1.2 times higher than YG 1029. 5. The frequencies of micronucleus appearing in lymphocyte of the circulating blood of dye handling workers and the control were 5.65+/-2.97% and 4.65+/-0.97%, respectively. And the difference was statistically significant.


Subject(s)
Air Pollutants , Kerosene , Lymphocytes
2.
Korean Journal of Preventive Medicine ; : 27-41, 1973.
Article in Korean | WPRIM | ID: wpr-87074

ABSTRACT

In order to provide some basic data for the control of air water pollution in Korea, the suthors have estimated the amount of air and water pollutant emitted from industries which are employed over 20 employes. This study have done from July 1, 1972 to the end March 1973. The results are as follows: 1. Total number of establishments tith over 20 employees is 5,197 in Korea and the largest gorup establishments was the manufacturing of texttiles with 1,363 establishments(26.2%). 2. By order of number of employees it was observed that there 2,800 industries with 20-59(53.9%) employees, 1,101 with 50-99(21.2%), 571 with 100-199(11.0%), 501 with 200-499(9.6%) and 225with over 500(4.3%) respectively. 3. By order of regional distribution, it was observed that there were 2,257 industries in Seoul (43.3%) and 736 industries in Pusan(14.2%). 4. Industrial coal consumption was 596,154 M/T in 1972, but it'11 be 315,000 M/T in 1980, Fuel consumption was 4,972,000 K1 in 1972, and estimated volume will be 19,3700,000 K1 in 1980. 5. Ttotal amounts of air polutants emitted from industris by fuel combustion were sulfur oxides 79,459 tons, carbon monoxide 33,908 tons, particulate 31,304 tons and hydrocarbon 30,280 tons in 1972 but in 1990 there will be sulfur oxides 1,010,474 tons, nitrogen oxides 204,575 tons, carbon monoxide 68,014 tons, particulate 64,820 tons and hydrocarbon 67,622 tons, respectively. 6. Annual emitted air pollutants through the working processes were sulfur oxides 91,250 tons and nitrogen oxides 32,485 tons in 1972, but sulfur oxieds 118,625 tons and nitrogen oxides 42,555 tons will be present in 1980, respectively. 7. Annual emitted air pollutants by national unit area amounted to 0.77 tons/km2/year in 1965 and 14.7 ton/km2/year in 1980. 8. Total industrial wastes from all industries in Korea were estimated at 810,360 tons/day in 1972; manufacturing of chemicals and plastic products showed the highest amount of wastes at 470,000 tons/day. 9. The amounts of water pollutants due to industrial wastes were the .B.O.D., 471.5 tons/day,suspended solid 331.5 tons/day, CN, 2.3 tons/day, and Cr. 3. 4 tons/day in 1972, but it might be evident of a B.O.D of 3.388 tons/day, suspended solid 2,544 tons/day, CN 20.1 tons/day, and 26.5 tons/day in 1990. 10. Total population equivalent of B.O.D. was 943,000 in 1972, and the estimated value in 1990 will be6, 780, 000.


Subject(s)
Air Pollutants , Carbon Monoxide , Coal , Industrial Waste , Korea , Nitrogen Oxides , Plastics , Seoul , Sulfur , Sulfur Oxides , Water Pollutants , Water Pollution