Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 128-135, 2015.
Article in Chinese | WPRIM | ID: wpr-637546

ABSTRACT

Objective To investigate the application value of transvaginal three-dimensional ultrasound combined with tomographic ultrasound imaging (TUI) in the diagnosis of early ectopic pregnancy. Methods One hundred and twenty patients with 4 to 6 weeks menopause were collected. All of the cases were clinical suspected of ectopic pregnancy and the surgical pathology and clinical follow-up results of each case were obtained. Both transvaginal two dimensional ultrasound imaging and three-dimensional ultrasound imaging combined with TUI technique were applied in order to make a diagnosis based on ultrasonographic characteristics for each of the case;surgical pathology and clinical follow-up results were compared with the ultrasonographic diagnosis so as to analysis and conclude the ultrasonographic imaging characteristics of cases misdiagnosed or missed diagnosed by transvaginal two-dimensional ultrasound imaging and three-dimensional ultrasound imaging joint TUI technique. Results One hundred and two cases were confirmed as ectopic pregnancy by surgical pathology and clinical follow-up results among 120 patients and eighteenth cases were confirmed as intrauterine pregnancy. Comparing surgical pathology and clinical follow-up results with the ultrasonographic diagnosis showed:(1) Ninety-two cases of tubal pregnancy:80 cases were correctly diagnosed by transvaginal two-dimensional ultrasound imaging (86.9%, 80/92) while 84 cases by three-dimensional combined with TUI technique (91.3%, 84/92); 8 cases were missed diagnosed by both two methods;4 cases were misdiagnosed by transvaginal two-dimensional ultrasound imaging while zero case by three-dimensional combined with TUI technique. Ultrasonographic imaging characteristics:adnexal masses presented as“Donut”sign which was similar to gestational-sac or masses with irregular boundary. The majority of the masses presented as clear boundaries and internal structure and had obvious margins with fallopian tube. A total 36 cases of unruptured tubal pregnancy were correctly diagnosed by the two methods while 43 cases of abortion type and 5 cases of ruptured type were correctly diagnosed. (2) Ten cases of uterine cornual pregnancy:6 cases were correctly diagnosed by transvaginal two-dimensional ultrasound imaging (60.0%, 6/10) while 9 cases by three-dimensional ultrasound imaging joint TUI technique (90.0%, 9/10);4 cases were misdiagnosd by transvaginal two-dimensional ultrasound imaging and 1 case by three-dimensional ultrasound imaging joint TUI technique. Ultrasonographic imaging characteristics:the gestational-sac was located in the uterine horn, 6 cases of gestational-sac was not connected with endometrium showed by transvaginal two-dimensional ultrasound imaging while 9 cases were clearly showed by three-dimensional ultrasound imaging joint TUI technique that the gestational-sac was connected with endometrium, especially in the coronal-section. The surrounding decidua circumvoluted the gestational-sac was unclear in 4 cases by transvaginal two-dimensional ultrasound imaging and in 9 cases by three-dimensional ultrasound imaging joint TUI technique. And‘interstitial line’ sign appeared in 4 cases showed by transvaginal two-dimensional ultrasound imagingwhile 6 cases by three-dimensional ultrasound imaging joint TUI technique. (3) Cases missed diagnosed and misdiagnosed:8 cases of early ectopic pregnancy were missed diagnosed both by transvaginal two-dimensional ultrasound imaging and three-dimensional ultrasound imaging joint TUI. The reasons we concluded were as follow:‘false gestational-sac’ located in the uterine cavity;the location of the gestational-sac was so closed to uterine cavity. Four cases of tubal pregnancy and 4 cases of uterine cornual pregnancy were misdiagnosed by transvaginal two-dimensional ultrasound imaging. The location of the ectopic pregnancy mass and the gestational-sac of 7 cases of uterine cornual pregnancy were clearly showed by three-dimensional ultrasound imaging joint TUI and only 1 case was misdiagnosed. Conclusions Transvaginal three-dimensional ultrasound imaging combined with TUI technique can provide more detailed ultrasound diagnostic information and reduced missed diagnosis and misdiagnosis of the early ectopic pregnancy. The clinical application value of transvaginal three-dimensional ultrasound imaging combined with TUI technique in the diagnosis of early ectopic pregnancy was good.

2.
Chinese Journal of Trauma ; (12): 1125-1129, 2012.
Article in Chinese | WPRIM | ID: wpr-430750

ABSTRACT

Objective To investigate effects of exogenous substance P (SP) on proliferation of humau skin fibroblast (HSF) and expression of its monocyte chemoattractant protein-1 (MCP-1) under high glucose condition.Methods HSF cultured in high glucose DMEM medium were treated with SP of various concentrations at different time points.Levels of MCP-1 in the supernatants were determined by ELISA and time-effect relationship of SP regulating expression of MCP-1 was analyzed.Expression of MCP-1 mRNA in HSF was detected by semi-quantitative RT-PCR and Real Time-PCR,Conclusion,while cxpression of MCP-1 by Western blot.Proliferation of HSF treated with SP of different concentrations was detected by cell counting Kit-8 (CCK-8).Results MCP-1 had a strong expression at 8 hours after SP disposal (P <0.05) and reached the peak at 24 hours (P < 0.01).Meanwhile,MCP-1 expressed the most at 10 nmol/L and 100 nmol/L SP (P <0.01).SP significantly enhanced the expression of MCP-1 mRNA and its synthesis under high glucose condition,especially at the concentration of 10 nmol/L (P <0.01).Also,SP induced obvious proliferation of HSF at concentrations of 10 nmol/L and 1 000 nmol/L(P < 0.05).Conclusion SP promotes proliferation of HSF and expression of MCP-1 in high glucose DMEM medium,which may be of significance in promoting diabetic wound healing.

3.
Chinese Journal of Trauma ; (12): 79-82, 2012.
Article in Chinese | WPRIM | ID: wpr-423874

ABSTRACT

ObjectiveTo develop a new sutureless technique (photochemical tissue bonding,PTB ) for repair of corneal perforation. Methods A total of 60 rabbits were used for creating corneal perforation models.The corneal perforation on the left eye was repaired by sutures and the injury on the right eye was fixed with the use of amniotic membrane with PTB.The outcomes of the two mentioned repair methods were compared by observing the leakage of aqueous and the morphology of the anterior chamber at different instants,measuring the intraocular pressure (IOP) and observing the formation of neo-vessels and scars of cornea in the use of histological analysis. Results There was no leakage of aqueous and no difference for morphology evaluation in both treatments.PTB could adhere AM on the cornea to restore the corneal perforation.The peak IOP in the PTB treatment group at days 0,7 and 14 postoperative [ (531.2 ±49.5) mm Hg,(542.6 ±74.8) mm Hg and (603.9 ±69.1) mm Hg,respectively] was significantly higher than that in the suture group at the same instants [ (41.3 ±12.7) mm Hg,(142.6 ±25.4) mm Hg and (333.3 ± 66.7) mm Hg,respectively] (P <0.O1 ).Compared with suture repair,the treatment with PTB resulted in a better outcome of wound healing with less neo-vessels and less scars of cornea. Conclusion PTB treatment for repair of corneal perforation is superior to suture repair.

4.
Chinese Journal of Trauma ; (12): 854-858, 2012.
Article in Chinese | WPRIM | ID: wpr-420623

ABSTRACT

Objective To establish a stable animal model for sequentially dynamic and direct monitoring of the skin wound infection. Methods The mice with full-thickness skin incisions were replicated. After immediate subcutaneous suture,the mice were randomly divided into four groups,ie,Group A was inoculated with 50 μl sterile PBS solution),Groups B,C and D were inoculated with 50 μl suspension containing 1 × 106,1 × 108 and 1 × 1010 colony forming unit (CFU)/ml bioluminescent methicillin-resistant staphylococcus aureus (MRSA) respectively.Then,the diet behavior of each group was observed and the mean weight and mortality of each group were also recorded at different time points.The bioluminescent intensity of fluoresce in the wounds was recorded at different time points by using the charge-coupled device (CCD) based imaging system.Local wound tissues were incised at 24 hours after inoculation for HE staining so as to observe wound inflammatory reaction in each group.Wound healing time of each group was also recorded. Results ( 1 ) Average weight:Groups A and B showed unobvious changes in weight; Group C lightened until day 3 after inoculation and then recovered gradually to the preinoculation level at day 14; Group D lightened gradually until death.(2)Mortality:Groups A and B had no death; Group C had 10% deaths at day 14; Group D had 100% deaths.(3) Bioluminescent intensity of wounds:Groups A and B showed a gradual weakened luminescence since the day of inoculation and had almost complete disappearance at days 5 and 7 respectively; there was no sign of obvious increase or decrease in Group C from the day of inoculation till day 14 ; Group D had a gradual increase since the day of inoculation and the luminous area expanded until the death.(4) HE staining at 24 hours after inoculation:all the four groups showed inflammatory cell infiltration,especially in Groups C and D.(5) Wound healing time:wound healed at days 5 and 7 after inoculation in Groups A and B; the wounds showed no healing even at day 14 in the Group C,but the wounds length and area did not show obvious enlargement or diminishment ; the wounds extended gradually until the death in the Group D,since the day of inoculation. Conclusions The inoculation of 50 μl suspension with 1 × 108 CFU/ml bioluminescent MRSA to full-thickness skin incision rats allows direct,real-time dynamic and continuous detection of the occurrence and development of the wound infections.The infection model is easy to make and has stability and high repeatability.

SELECTION OF CITATIONS
SEARCH DETAIL