Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Pharmacological Bulletin ; (12): 1219-1224, 2021.
Article in Chinese | WPRIM | ID: wpr-1014362

ABSTRACT

Aim To study the protective effect of proanthocyanidins extracted from Rubus amabilis Focke (RPC) on the pancreatic tissues of diabetic mice and the underlying mechanism. Methods C57BL/6 male mice were given a high-sugar and high-fat diet combined with an intraperitoneal injection of STZ to establish the diabetic model. The mice whose FBG were higher than 16. 7 mmol · L

2.
Chinese Journal of Interventional Cardiology ; (4): 330-335, 2018.
Article in Chinese | WPRIM | ID: wpr-702348

ABSTRACT

Objective To explore the validity of lead aVL in combination with lead V1 for identifying idiopathic outflow tract premature ventricular contractions(PVCs)originating from aortic sinus cusp(ASC).Methods This study consecutively enrolled 102 idiopathic outflow tract PVCs patients who underwent radiofrequency catheter ablation at the Second Xiangya Hospital,Central South University between January 2015 and August 2017.We compared the QRS wave amplitudes in the surface twelve leads electrocardiography between PVCs originating from ASC and right ventricular outflow tract(RVOT).Results(1)The origin sites of PVCs were ASC(n=28,27.5%)and RVOT(n=74,72.5%).The lead V1R/S wave amplitude ratio and lead aVL S wave amplitude were significantly higher in the ASC group than in the RVOT group[(1.14±1.32)vs.(0.16±0.18),P<0.001;(0.99±0.36)mV vs.(0.56±0.26)mV,P<0.001].The areas under the receiver operating characteristic curve(AUCs)and 95%confidence intervals of V1R/S wave amplitude ratio and aVL S wave amplitude had relatively larger AUCs which were 0.894(0.824-0.964)and 0.831(0.749-0.912),with the cut-offs of 0.25 and 0.80 respectively.(2)The sensitivity,specificity and accuracy of the lead V1R/S wave amplitude ratio>0.25 to identify ASC originating PVCs were 78.9%,83.7%and 82.4%,respectively.The sensitivity,specificity and accuracy of the lead aVL S wave amplitude>0.80 mV were 78.6%,85.1%and 83.3%,respectively.The lead aVL S wave amplitude>0.80 mV in combination with the lead V1R/S wave amplitude ratio>0.25 was applied to developed a new diagnostic approach and the sensitivity,specificity and accuracy were 60.7%,93.2%and 84.3%,respectively.Conclusions Lead aVL in combination with lead V1 could be applied to develop a more accurate method for identifying ASC originating PVCs.

3.
Chinese Journal of Interventional Cardiology ; (4): 682-688, 2017.
Article in Chinese | WPRIM | ID: wpr-702304

ABSTRACT

Objective To summarize the ablation methods,and to provide experience reference for the treatment of pulmonary since cusp(PSC)-derived ventricular arrhythmia(VA)with ablation. Methods A retrospective analysis of the clinical data of 19 patients undergoing catheter ablation for PSC-derived VA in Cardiac Intervention Therapy Center,The Second Xiangya Hospital of Central South University between January 2013 and March 2016 was conducted. Results Among the 19 patients,PSC-derived VA originated from the lower regions of the pulmonary sinuses,generating from the right,left,and anterior sinuses of the PSC were identified in 5,7,and 7 patients,respectively. Twelve patients with PSC-derived VAs originating from the right and anterior sinuses underwent successful reversed U-curve catheter ablation,while the other 7 patients with arrhythmias originating from the left sinus underwent successful ablation with the conventional method(non-reversed U-curve catheter ablation). All the patients were followed-up for 6 to 31 months,and no recurrence of VA or complications were recorded. Conclusions Reversed U-curve catheter ablation is suitable for VA originating from the right and anterior PSCs,while conventional ablation can be used for those originating from the left PSCs.

SELECTION OF CITATIONS
SEARCH DETAIL