Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Peking University(Health Sciences) ; (6): 62-68, 2020.
Article in Chinese | WPRIM | ID: wpr-942142

ABSTRACT

OBJECTIVE@#To explore the preliminary application of "biocopy function" in digital technology of temporary crown in severe tooth attrition, so as to reduce the difficulty of final restoration adjustment in severe tooth wear cases, and save clinical time.@*METHODS@#Twelve patients aged between 40 and 65 years with severe tooth attrition were recruited in this study. The experimental group (6 cases, 3 females and 3 males) used the method of digital copy of temporary restoration shape when making the final restoration, and the control group (6 cases, 3 females and 3 males) used the traditional method to make the final restoration. The mean time of central occlusal adjustment and protrusive and lateral occlusal adjustment of each crown, the number of follow-up visits of the patients were recorded and statistically analyzed. The occlusal comfort of the first and the third months after wearing the prosthesis was evaluated by the patients, and the difference of the occlusal comfort of the final prosthesis made by the two methods was compared (the full score was 10 points). The occlusal adjustment time and occlusal comfort score were used as measurement data. Single sample t test was used. The number of follow-up visits was count data. Rank sum test was used for non-normal continuous variables.@*RESULTS@#The mean occlusal time of each crown adjustment in the experimental group was significantly lower than that in the control group (P < 0.01), and the median number of follow-up visits in the experimental group was lower than that in the control group (P < 0.01). The average occlusal comfort score of the experimental group was higher than that of the control group at the first time (P < 0.01). After three months of crown wearing, the median occlusal comfort score of the experimental group was higher than that of the control group (P < 0.05).@*CONCLUSION@#In the case of severe tooth attrition, it is feasible to use the "biocopy function" in the design software to design the final prosthesis, which is conducive to reduce the difficulty of adjustment and achieve predictable functional and aesthetic effects, which is of great significance to save clinical time and improve the accuracy of restoration.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Computer-Aided Design , Crowns , Tooth
2.
Journal of Peking University(Health Sciences) ; (6): 335-339, 2019.
Article in Chinese | WPRIM | ID: wpr-941816

ABSTRACT

OBJECTIVE@#To explore a novel method for fabricating removable partial dentures (RPDs) using polyetheretherketone (PEEK) by computer-aided design and computer-aided manufacturing (CAD/CAM) technologies and to evaluate their fits for different assemblies in vitro.@*METHODS@#A standard stone cast of mandibular partial edentulous jaw was scanned using a lab scanner. Based on the digital cast, thirteen complete RPDs were designed combing dental CAD software and reverse engineering software, and then fabricated using PEEK by milling machine. Fits of assemblies were evaluated quantitatively by measuring the spaces between RPDs and casts. The gaps between RPDs and stone casts in different assemblies were duplicated using light-body silicone impression material and then measured using three-dimensional (3D) digital analysis methods in virtue of a dedicated software. Statistically, one-way analysis of variance (ANOVA) was used to compare the difference of gaps among assemblies in different shapes such as occlusal rest, denture base, and major connector. Paired-samples t test was used to compare the gaps difference for the similar shape assemblies in different areas.@*RESULTS@#One-piece PEEK RPDs were successfully designed and fabricated by CAD/CAM, and all the RPDs were well-seated on stone casts. The gaps between occlusal rests and casts [(84.3±23.6) μm] were significantly larger than those of denture bases [(32.5±27.8) μm] and major connectors [(49.9±47.0) μm], which meant that the fits of denture bases and major connectors were better than that of occlusal rests. However, the fits of all assemblies could be accepted clinically. For the similar shape assemblies in different areas, there were no significantly differences for gaps between distal extension denture bases [(25.1±55.3) μm] and non-extensive denture bases [(41.5±17.7) μm]. The gaps of occlusal rests adjacent and nonadjacent to the edentulous space were (86.1±29.8) μm and (80.8±42.1) μm respectively and there were no significantly difference between them either. These results implied that different locations had no apparent effect on the fits of assemblies.@*CONCLUSION@#With the computer-aided design and computer-aided manufacturing technology, PEEK can be used to fabricate one-piece removable partial dentures. And all assemblies of the one-piece PEEK RPDs showed satisfying fits in vitro, indicating a promising clinical application in the future.


Subject(s)
Benzophenones , Computer-Aided Design , Denture, Partial, Removable , Ketones , Polyethylene Glycols , Polymers
3.
Journal of Peking University(Health Sciences) ; (6): 78-84, 2018.
Article in Chinese | WPRIM | ID: wpr-691463

ABSTRACT

OBJECTIVE@#To develop a digital workflow of orthodontic-prosthodontic multidisciplinary treatment plan which can be applied in complicated anterior teeth esthetic rehabilitation, in order to enhance the efficiency of communication between dentists and patients, and improve the predictability of treatment outcome.@*METHODS@#Twenty patients with the potential needs of orthodontic-prosthodontic multidisciplinary treatment to solve their complicated esthetic problems in anterior teeth were recruited in this study. Digital models of patients' both dental arches and soft tissues were captured using intra oral scanner. Direct prosthodontic (DP) treatment plan and orthodontic-prosthodontic (OP) treatment plan were carried out for each patient. For DP treatment plans, digital wax-up models were directly designed on original digital models using prosthodontic design system. For OP treatment plans, virtual-setups were performed using orthodontic analyze system according to orthodontic and esthetic criteria and imported to prosthodontic design system to finalize the digital wax-up models. These two treatment plans were shown to the patients and demonstrated elaborately. Each patient rated two treatment plans using visual analogue scales and the medians of scores of two treatment plans were analyzed using signed Wilcoxon test. Having taken into consideration various related factors, including time, costs of treatment, each patient chose a specific treatment plan. For the patients chose DP treatment plans, digital wax-up models were exported and printed into resin diagnostic models which would be utilized in the prosthodontic treatment process. For the patients chose OP treatment plans, virtual-setups were used to fabricate aligners or indirect bonding templates and digital wax-up models were also exported and printed into resin diagnostic models for prosthodontic treatment after orthodontic treatment completed.@*RESULTS@#The medians of scores of DP treatment plan and OP treatment plan were calculated and analyzed by IBM SPSS 20. The median of scores of DP treatment plan was 8.4, the minimum value was 6.9 and the maximum value was 9.3. The median of scores of OP treatment plan was 9.0, the minimum value was 7.9 and the maximum value was 9.6. The median of scores of OP was significantly higher than that of DP (Z=-3.23, P<0.01). Finally, 12 patients chose OP treatment plans and 8 patients chose DP treatment plans.@*CONCLUSION@#For cases with complex esthetic problems in anterior teeth, a digital workflow can demonstrate final treatment outcome and help patients make suitable treatment decisions. In our study, the orthodontic-prosthodontic multidisciplinary treatment plan is feasible which can provide predictions of treatment outcome and improve esthetic outcome with patients' satisfaction.


Subject(s)
Humans , Dental Arch , Esthetics, Dental , Prosthodontics , Tooth
SELECTION OF CITATIONS
SEARCH DETAIL