Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
China Medical Equipment ; (12): 96-98, 2015.
Article in Chinese | WPRIM | ID: wpr-467575

ABSTRACT

Objective:To investigate the CT value added value of the mean of critical value in the diagnosis of giant cell tumor clinical sensitivity.Methods: Aretrospective analysis, selected from March 2013 to November 2014, the clinical data of 120 patients with bone tumors treated, they can be divided into two groups at random, control group and the observer, 60 cases in each group, observer for patients with giant cell tumor of bone, the control for the patients with giant cell tumor of bone. Each patient chose three ROI, the added value of the mean values of enhanced CT and CT values mean as observed values, under the experience of observation analysis of patients with giant cell tumor of the added value of CT values mean critical value and its sensitivity in the clinical diagnosis of giant cell tumor of bone.Results: The observation group of patients after CT enhanced scan display area average CT value of HU(108±39)HU was significantly higher than the control group(82±78)HU CT value(t=3.348, P<0.05), statistically significant difference; Through the ROC curve analysis, found that when the added value of CT values mean acuity 96.5 as critical, sensitivity and specificity of diagnosis of giant cell tumors of bone are 90.9% and 90.9% respectively; When the CT value added value of the mean acuity 41.5 HU as the critical point, the sensitivity and specificity of diagnosis of giant cell tumor bone were 98.9%, 48.1% respectively.Conclusion: The bone giant cell average CT value added value of diagnosis of critical value of 96.5HU 41.5HU, and high sensitivity, but the specificity is low, the added value of CT values help determine the existence of the giant cell tumors of bone.

2.
China Medical Equipment ; (12): 81-83, 2014.
Article in Chinese | WPRIM | ID: wpr-457424

ABSTRACT

The iterative reconstruction algorithm in the main function is to improve the subjective and objective image quality in CT, compared with the traditional algorithm, can significantly reduce the signal-to-noise ratio, contrast to noise ratio, make the CT image quality is good, and more recently, studies have found that the application of the algorithm or can reduce the use of radiation dose, so use foreground is very good, the technology based on this the paper focus on the development of technology, neusoft medical iteration, and the second generation iteration technology in general, the application of CT examination and evaluation are analyzed.

3.
Chinese Journal of Pathophysiology ; (12)1986.
Article in Chinese | WPRIM | ID: wpr-529048

ABSTRACT

AIM: To investigate the influence of GM-CSF on human vascular endothelial cells induced to form new blood vessels and the role of VEGF.METHODS: HUVECs were cultured by Matrigel to set up a stable angiogenesis system with the stimulating factors.The rhGM-CSF concentration-dependent and time-dependent effects and the role of VEGF165 were detected.CD34 was measured by immunochemical staining and numbers of vessel formation was calculated under microscopic observation.RESULTS: After treatment with rhGM-CSF at various concentrations and at different time points,the numbers of vessel formation increased in a dose-dependent and time-dependent manner.In the presence of VEGF165,the numbers of vessel formation increased evidently.CONCLUSION: HUVECs were induced to develop tubular structure in vitro cultured with Matrigel.GM-CSF promotes human vascular endothelial cells to form vessel-like structure in vitro in a dose-dependent and time-dependent manner.VEGF also in vitro promotes human vascular endothelial cells to form new vessel-like structure.

SELECTION OF CITATIONS
SEARCH DETAIL