Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Acta Pharmaceutica Sinica ; (12): 1279-88, 2014.
Article in Chinese | WPRIM | ID: wpr-457171

ABSTRACT

The tumor multidrug resistance reversal effect of NPB304, a novel taxane, was studied. MTT assay was used to determine the IC50 of chemotherapy drugs. Western blotting assay was applied to analyze the expression of P-glycoprotein (P-gp). The effect of compounds on the P-gp function and P-gp ATPase activity was determined by rhodamine 123 (Rh123) accumulation assay and analysis kit, respectively. Molecular docking was employed to predict the binding force between compounds and P-gp. Transmembrane transport of NPB304 was analyzed using MDCK II and MDR1-MDCK II cell model. NPB304 displayed multidrug resistance reversal effect on KBV cells and MCF-7/paclitaxel cells, NPB304 collaborative with P-glycoprotein (P-gp) inhibitors verapamil enhanced the reversal activity, specifically, 10 μmol x L(-1) verapamil in combination with paclitaxel reversed resistance by 56.5-fold, while combined with NPB304 increased the reversal fold; NPB304 synergistically increased Rh123 accumulation in the resistant cells when combined with verapamil, and NPB304 at 0-1 μmol x L(-1) enhanced the ATPase activity activated by verapamil was observed. NPB304 existed the hydrophobic interactions with the TM regions of P-gp, and the binding force between NPB304 and the A chain of the TM region was stronger. P-gp ATPase activity assay demonstrated NPB304 at lower concentrations (0-1.5 μmol x L(-1)) could activate the P-gp ATPase, playing a role on inhibition of P-gp function. However, NPB304 did not have an obvious feature of P-gp substrate. NPB304 exerted itself and synergy with verapamil activity on reversing tumor resistance via inhibiting the P-gp function.

2.
Chinese Journal of Medical Instrumentation ; (6): 446-448, 2011.
Article in Chinese | WPRIM | ID: wpr-325957

ABSTRACT

Through five experiments, such as "Circle", "square", "side that does not shake", "burning edge", "filter", this paper discussed the effect of different experimental methods of polypropylene fiber liquid filtration membrane particles shedding. The results show that: the particles falling off the edge of the polypropylene fiber Double-sided liquid filtration membrane are very important and must be considered off the evaluation of particle pollution.


Subject(s)
Equipment Failure , Filtration , Methods , Particle Size , Polypropylenes
3.
Chinese Journal of Medical Instrumentation ; (6): 126-128, 2010.
Article in Chinese | WPRIM | ID: wpr-281145

ABSTRACT

Compare and analyze the standards related to centrifuge apparatus and make corresponding suggestions in allusion to the problems existed in the test method and physical performance during product standard drafting process.


Subject(s)
Blood Component Removal , Centrifugation , Reference Standards , Device Approval , Reference Standards
SELECTION OF CITATIONS
SEARCH DETAIL