1.
Chinese Journal of Blood Transfusion ; (12): 818-822, 2023.
Article in Chinese | WPRIM | ID: wpr-1004749

ABSTRACT

【Objective】 To establish an enzyme-linked immunosorbent assay (ELISA) method for the determination of residual human coagulation factor Ⅺ in human prothrombin complex and validate the method. 【Methods】 Human factor Ⅺ was reacted with the capture antibody coated on the microtiter plate. After appropriate washing steps, biotinylated primary antibody was bound to the captured protein. Excess primary antibody was washed away and bound antibody was reacted with horseradish peroxidase conjugated streptavidin. TMB substrate was used for color development at 450 nm. The dilution reliability, accuracy, specificity, repeatability, intermediate precision, linearity, range and durability were verified. 【Results】 The verification results showed that the accuracy and specificity of this method met the experimental requirements, with an average recovery rate of 109.2% and RSD of 6.93%. The repeatability RSD was 6.78%, and the intermediate precision RSD was 6.75%, indicating good precision. The linear regression correlation coefficient of standard curve was 0.999 9, showing good accuracy and precision within the linear range. The durability was verified by the incubation time and the validity period of reagent kit opening. The results showed that the RSD of the incubation time change was 6.62%, indicating that the incubation time of this detection method was controlled between 28 to 32 minutes, and there was no significant impact on the results. The RSD of the detection results before and after the reagent kit was opened and stored under conditions for 7 days was 3.84%, indicating that the preservation of the reagent kit according to the conditions for 7 days after opening has no effect on the FⅪ detection results. Both indicated that the method had good durability. The dilution reliability results showed that there was a "hook" effect in the detection of FⅪ residue in human prothrombin complex, which could be solved by diluting 100 to 200 times. 【Conclusion】 This method can be used for the determination of FⅪ residues of human prothrombin complex in laboratory.

2.
Chinese Journal of Burns ; (6): 155-158, 2002.
Article in Chinese | WPRIM | ID: wpr-289221

ABSTRACT

<p><b>OBJECTIVE</b>To observe the effects of respiratory support with high frequency jet ventilation (HFJV) in severely burned patients with inhalation injury during early postburn stage.</p><p><b>METHODS</b>Twenty severely burned patients with TBSA of 79.6 +/- 29.3% and inhalation injury were enrolled in the study. Nineteen cases received tracheostomy after admission and only one received nasal intubation. All the patients underwent HFJV to correct hypoxia. The changes in blood gas analysis, respiratory rate and pulse were recorded before and 11 days after the ventilation.</p><p><b>RESULTS</b>Tracheostomy was performed on 2.7 +/- 2.4 postburn days (PBDs), and HFJV was given during 4.4 +/- 2.9 PBDs. PaO(2) was evidently higher during 1 - 3 days after HFJV than that before the ventilation (P < 0.01) and remained at high level for 1 week after HFJV. There was no change in PaCO(2), respiratory rate and pulse during the ventilation.</p><p><b>CONCLUSION</b>HFJV was beneficial in improving oxygenation and without any obvious side effects during the early management of severely burned patients with inhalation injury. This might be an optimal respiratory support pattern.</p>


Subject(s)
Adult , Humans , Middle Aged , Blood Gas Analysis , Burns , General Surgery , High-Frequency Jet Ventilation , Smoke Inhalation Injury , General Surgery , Therapeutics , Tracheostomy
SELECTION OF CITATIONS
SEARCH DETAIL