Chinese Journal of Blood Transfusion ; (12): 290-292, 2021.
Article in Chinese | WPRIM | ID: wpr-1004567

ABSTRACT

【Objective】 To discuss the interference of anti-CD47 in pre-transfusion test and the mitigation measures. 【Methods】 Blood sample of one patient received anti-CD47 treatment was collected to conduct routine serological tests including ABO/Rh phenotype, direct anti-human globulin test, irregular antibody screening, antibody identification and cross-match. Packed platelet from multiple type O blood donors was used to absorb with patient′s plasma. The patient′s plasma was absorbed with CCDee, ccDEE and ccdee red cells, respectively. Anti-IgG monoclonal Gamma-clone which lacks reactivity with human subclass IgG4 was used to perform antibody screening and cross-match. Capture-R was used to perform antibody screening. 【Results】 The direct anti-human globulin test was positive(1+ ), the reactivity in all phases was strong positive(3+ -4+ ). The anti-CD47 was eliminated after platelet and red cells absorption. Antibody screening became negative using Gamma-clone and Capture-R, and cross-match successfully using Gamma-clone. 【Conclusion】 Anti-CD47 monoclonal antibody can interfere with pre-transfusion test and cross matching. To remove the interference of anti-CD47 requires the use of Gamma-clone anti-IgG in the indirect antiglobulin testing or Capture-R.

2.
Chongqing Medicine ; (36): 2503-2504,2507, 2013.
Article in Chinese | WPRIM | ID: wpr-583172

ABSTRACT

Objective To improve the reliability and accuracy of WBC counting in cerebrospinal fluid (CSF) ,this article is stud-ying the improved method of WBC counting in CSF by finding out the optimum percentage of CSF specimen with the most suitable concentration of acetic acid .Methods CSF specimen was mixed with different acetic acid at different ratio respectively .WBC counts were performed in 5 minutes on diluted samples of various concentrations .A series of 20 CSF specimens were analyzed via the proposed assay and conventional method .The average value and coefficient of variation (CV) of WBC count of each sample were c compared and analyzed .Results The optimum percentage of CSF sample was obtained at 60∶40 ratio .In this percentage , the maximal WBC count (189/μL) was obtained compared that of conventional method (161/μL) .Moreover ,the CV of the WBC counts in this percentage (7% ) was also lower than that of the conventional method (18% ) .Conclusion The reliability and accur-ancy of WBC counting in CSF was the optimum percentage of CSF specimen and 5% acetic acid was 60 :40 .It may lead to a more reliable ,accurate and standard way of WBC counts in CSF .

SELECTION OF CITATIONS
SEARCH DETAIL