Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Article in Chinese | WPRIM | ID: wpr-1021783

ABSTRACT

BACKGROUND:Patients with degenerative cervical spondylosis often suffer from changed varicosity of the cervical spine,unbalanced neck-shoulder muscular strength,and descending power. OBJECTIVE:To probe into the correlation between sagittal curvature parameters and pain threshold for neck-shoulder muscles in degenerative cervical spondylosis. METHODS:Totally 50 patients with degenerative cervical spondylosis received treatment at the 3D Printed Outpatient Center of Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine from January 2022 to March 2023 were included in the study.After excluding the 10 patients of cervical lateral projection that failed to meet the measurement conditions,the cervical lateral projections were shot to measure the following iconography parameters:Borden value and C2-7 Cobb angle as well as pain thresholds on the midpoint of the superior trapezius muscle in bilateral bundles and at 1 cm beside the C5-6 interspike.The correlation between sagittal curvature parameters and pain threshold of neck-shoulder muscles in degenerative cervical spondylosis was analyzed. RESULTS AND CONCLUSION:(1)The Borden value of sagittal curvature showed a moderately positive correlation with the bundle pain threshold in the left upper trapezius muscle,the bundle pain threshold in the right upper trapezius muscle,and the pain threshold at the 1 cm of the left side beside the C5-6 interspike(r=0.498,P<0.01;r=0.448,P<0.05;r=0.405,P<0.05)and a weak positive correlation with the pain threshold at the 1 cm of the right side beside the C5-6 interspike(r=0.322,P<0.05).(2)The C2-7 Cobb angle showed a weak positive correlation with the left squared myalgia threshold(r=0.355,P<0.05),and there was no correlation with the pain threshold of the left trapezius muscle and the pain threshold at the 1 cm of both sides beside the C5-6 interspike.(3)There was a correlation between the pain threshold of the neck-shoulder muscles,and a high correlation between the pain threshold of the left and right muscles and the pain threshold within the left and right side muscles,indicating that the neck-shoulder muscles are consistent and may be related to the coordination of the neck-shoulder movements.

2.
Article in Chinese | WPRIM | ID: wpr-1021898

ABSTRACT

BACKGROUND:Short-term wearing of cervical brace combined with shoulder and neck muscle exercise can significantly improve the symptoms of early cervical spondylosis.After stopping wearing cervical brace,patients'symptoms are easy to recur,which may be due to the lack of cervical curvature correction function. OBJECTIVE:To analyze the effect of 3D printed personalized cervical orthopedic brace for adjusting cervical curvature in the treatment of early cervical spondylosis. METHODS:From January 2021 to January 2023,30 patients with early cervical spondylosis in the Shanghai Fifth People's Hospital,Fudan University were studied,including 11 males and 19 females,with a mean age of(31.7±6.6)years old.All patients customized and wore 3D printed personalized cervical orthopedic braces for 3 hours a day for continuous 12 weeks.Borden value of cervical curvature,pain threshold of shoulder and neck muscles,cervical dysfunction index,and visual analog scale score in 30 patients were recorded before and 4 and 8 weeks after treatment. RESULTS AND CONCLUSION:(1)Compared with before treatment,the difference of Borden value of cervical curvature,right trapezius tenderness threshold,and cervical dysfunction index was not significant in 30 patients after 4 weeks of treatment(P>0.05).Visual analog scale score,left trapezius tenderness threshold,left and right C5C6 tenderness threshold were significantly improved(P<0.05).(2)Compared with before treatment,the cervical curvature Borden value,left and right trapezius tenderness threshold,visual analog scale score,left and right C5C6 tenderness threshold,and cervical dysfunction index of 30 patients were significantly improved after 12 weeks of treatment(P<0.05).(3)Compared with 4 weeks after treatment,the Borden value of cervical curvature,right trapezius tenderness threshold,visual analog scale score,left and right C5C6 tenderness threshold and cervical dysfunction index of 30 patients after 12 weeks of treatment were significantly improved(P<0.05).(4)The results show that short-term wearing of 3D printed personalized cervical orthopedic brace can improve the pain of patients with early cervical spondylosis,while long-term application has certain effect on the recovery of cervical curvature.

3.
Article in Chinese | WPRIM | ID: wpr-791283

ABSTRACT

Objective To investigate the feasibility of an accuracy evaluation method for 3D reconstructed bone model based on 3D reconstruction software Arigin3D Pro.Methods Pig femurs were used as solid models which were scanned by CT and MRI respectively.The scan data were imported into software Arigin3D Pro for 3D model reconstruction by 3 operators with different reconstruction experience (≤1 year,2 to 3 years,and ≥4 years,respectively).Each operator reconstructed the femurs 3 times and in each reconstruction measured the diameter of the femoral head,the length of the femur and the width of the knee joint at the distal end of the femur 3 times respectively using software Geomagic Wrap.The above parameters of the solid models were measured using a vernier caliper.The parameter values of reconstructed models and solid models were compared and the differences were analyzed.Results The measurements by Geomagic Wrap showed deviations between the CT and MRI reconstruction models and the solid models,and the maximum deviation percentages were 1.47% and 1.08%,respectively.The percentages of intra-operater difference ranged from 0.29% to 1.53%;the 3D models reconstructed by operators with different reconstruction experience were not identical.Conclusions It is a feasible accuracy evaluation method to compare key parameters between the 3D bone model reconstructed by software Arigin3D Pro and the real animal bone.The deviations of 3D reconstructed bone model based on CT and MR1 images are acceptable.The accuracy of 3D bone construction is related to the difference in operators.

4.
Article in Chinese | WPRIM | ID: wpr-796395

ABSTRACT

Objective@#To investigate the feasibility of an accuracy evaluation method for 3D reconstructed bone model based on 3D reconstruction software Arigin3D Pro.@*Methods@#Pig femurs were used as solid models which were scanned by CT and MRI respectively. The scan data were imported into software Arigin3D Pro for 3D model reconstruction by 3 operators with different reconstruction experience (≤1 year, 2 to 3 years, and ≥4 years, respectively). Each operator reconstructed the femurs 3 times and in each reconstruction measured the diameter of the femoral head, the length of the femur and the width of the knee joint at the distal end of the femur 3 times respectively using software Geomagic Wrap. The above parameters of the solid models were measured using a vernier caliper. The parameter values of reconstructed models and solid models were compared and the differences were analyzed.@*Results@#The measurements by Geomagic Wrap showed deviations between the CT and MRI reconstruction models and the solid models, and the maximum deviation percentages were 1.47% and 1.08%, respectively. The percentages of intra-operater difference ranged from 0.29% to 1.53%; the 3D models reconstructed by operators with different reconstruction experience were not identical.@*Conclusions@#It is a feasible accuracy evaluation method to compare key parameters between the 3D bone model reconstructed by software Arigin3D Pro and the real animal bone. The deviations of 3D reconstructed bone model based on CT and MRI images are acceptable. The accuracy of 3D bone construction is related to the difference in operators.

5.
Article in Chinese | WPRIM | ID: wpr-506008

ABSTRACT

Objective To establish a finite element model of rotator cuff which can be used to simulate the rotator cuff injury and to evaluate the biomechanical effects of rotator cuff surgery.Methods The Dicom CT images of the right shoulder of a Chinese healthy volunteer were used to establish models of the scapula,humerus and clavicle.The rotator cuff structures were separated and modeled based on the MRI images and anatomical knowledge.After the rotator cuff model was introduced into the finite element analysis software Abaqus 6.12,the anatomical positions were simulated when the shoulder was at 30° internal rotation,30° external rotation,30° abduction,30° adduction,30° flexion and 30° extension.Results When the shoulder was in 30° flexion,the average stress was 52.2 kPa on the supraspinatus,223.0 kPa on the inffaspinatus and the teres minor,and 90.4 kPa on the subscapularis.When the shoulder was in 30° extension,the average stress was 105.0 kPa on the supraspinatus,78.2 kPa on the infraspinatus and the teres minor,and 55.7 kPa on the subscapularis,indicating that the muscle and tendon of the supraspinatus was subjected to greater stress and the humerus and the scapula produced less stress compared with the shoulder in 30° flexion.Conclusion Since our finite element model of the rotator cuff can simulate common activities of the shoulder joint and obtain stress values of the corresponding rotator cuff muscles,it can be used in simulation of rotator cuff injury and its surgery.

SELECTION OF CITATIONS
SEARCH DETAIL