Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Physics ; (6): 239-244, 2019.
Article in Chinese | WPRIM | ID: wpr-754299

ABSTRACT

Objective To conduct a Meta-analysis for assessing the therapeutic efficacy and safety of doxorubicin-eluting bead transcatheter arterial chemoembolization (DEB-TACE) vs conventional TACE (C-TACE) in the treatment of hepatoeellular carcinoma (HCC).Methods The relevant studies on DEB-TACE and C-TACE for HCC were searched from PubMed,Web of Science and CK1N databases.The tumor responds and adverse events in the selected studies were analyzed with RevMan5.0 statistical software.Moreover,publication bias was assessed by a funnel plot.Results Thirteen studies with 1 325 HCC patients were finally included in this analysis.The tumor response to DEB-TACE was better than that to C-TACE (OR:2.28;95%CI [1.75,2.96];P<0.001 0).The risk of adverse events in DEB-TACE group was also lower than that in C-TACE group (RR:0.56;95% CI [0.32,0.97];P=0.04).Conclusion Compared with C-TACE,DEB-TACE is more effective and has lower risk of adverse events in the treatment of HCC.

2.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 2087-2089, 2012.
Article in Chinese | WPRIM | ID: wpr-427859

ABSTRACT

Objective To explore the differential diagnosis value of DWI ADC for breast lumps,improve the diagnosis of breast cancer specificity.Methods 93 patients with 105 breast tumors were performed with routine MR series and DWI,and the ADC values were measured.Results Lesions ADC values:average ADC value 43 benign lesions in 37 cases was(1.37±0.36)×10-3 mm2/s,the different value between max and min was(0.63±0.19)×10 -3s/mm2.Average ADC value of 62 malignant lesions in 58 patients was(0.90±0.53) × 10 -3 mm2/s,the different value between max and min was(0.91±0.27)×10-3 mm2/s.By statistical analysis,both average ADC values and the max and the min ADC difference value were very significantly different(P<0.01).Draw diagnosis benign and malignant lesions ROC curves,with ADC values 0.11×10 -3 mm2/s for critical value to judge benign and malignant standard,sensitivity was 67%,specificity was 72%.With 1.0×10- 3 mm2/s for critical value,specificity can raise to 84%,and sensitivity came to 60%.With the maximum and minimum ADC difference value 0.75 × 10-3s/mm2 for critical value,sensitivity was 67%,specificity was 68%.If with 0.80 for critical value,sensitivity was 53% and specificity 82%.Conclusion The average ADC values of DWI were significant for the identification of benign and malignant lesions.

SELECTION OF CITATIONS
SEARCH DETAIL