Chinese Journal of Radiation Oncology ; (6): 195-198, 2018.
Article in Chinese | WPRIM | ID: wpr-708166

ABSTRACT

Objective To investigate the precision of full six-degree target shift corrections using the ArcCHECK system.Metbods Fourteen patients receiving intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) in Fujian Medical University Cancer Hospital from May to September,2015 were selected.The first treatment setup errors were obtained using cone-beam computed tomography.The setup errors were simulated in ArcCHECK,and the full six-degree target shift corrections was used to correct the errors.The plans without and with setup errors and the plan with corrected setup errors were taken.The paired t-test was used to compare dose to agreement (DTA) and Gamma passing rates between the plan without setup errors and the plan with setup errors and plan with corrected setup errors.Results The DTA and Gamma passing rates were (96.76± 1.57)% and (98.35±0.92)% for the plan without setup errors,(59± 21.42) % and (62.86± 21.63) % for the plan with setup errors,and (91.41± 4.82) % and (94.11±4.33)% for the plan with corrected setup errors.There were significant differences between the plan without setup errors and the plan with setup errors and plan with corrected setup errors in DTA passing rate (t=6.64 and 5.13,both P<0.05) and Gamma passing rate (t=6.15 and 4.19,both P<0.05).Conclusions The full six-degree target shift corrections can be used in IMRT for NPC,with good results in correcting setup errors and improving the precision for IMRT dose distribution.

2.
Journal of Biomedical Engineering ; (6): 851-854, 2012.
Article in Chinese | WPRIM | ID: wpr-246546

ABSTRACT

Cone-beam CT (CBCT) of Elekta can be used to analyze the setup errors in intensity modulated radiotherapy. A total of 240 patients with head and neck cancer were chosen in the period from October, 2009 to October, 2010. Their CBCT images were obtained after initial setup, and registered to the planning CT images, and then the setup errors on translational directions (X, Y, Z) and on rotational directions (U, V, W) were obtained and analyzed. The results showed that the setup errors on translational directions in Y-axis and Z-axis were larger than in X-axis, and the setup errors on rotational directions in Y-axis was much more obvious than those on the other two directions, which should be taken care during the patient daily setup. It may be concluded that the CBCT system can improve the precision for radiotherapy.


Subject(s)
Humans , Cone-Beam Computed Tomography , Methods , Head and Neck Neoplasms , Diagnostic Imaging , Radiotherapy , Radiotherapy Setup Errors , Radiotherapy, Intensity-Modulated
3.
Chinese Journal of Radiation Oncology ; (6): 205-208, 2012.
Article in Chinese | WPRIM | ID: wpr-425858

ABSTRACT

ObjectiveTo analyze the correlation between primary tumor volume (PTV) and prognosis of nasopharyngeal carcinoma ( NPC ) treated by intensity-modulated radiotherapy ( IMRT ).Methods330 NPC patients treated by IMRT were included.Pretreatment computerized tomography image were input into tree-dimensional treatment-planning system,in which the primary tumor volume were calculated automatically.The receiver operating characteristic curve was used to determine the best cut-off point of PTV.Within the framework of UICC 2002 T stage,The PTV was divided into four groups:V1 < 10cm3,V2 10-25 cm3,V3 > 25-50 cm3 and V4 > 50 cm3.Kaplan-Meier and Logrank test was used to analyze the survival,Cox proportion risk regression model were used to analysis the correlation between PTV and prognosis.ResultsThe mean PTV for all NPC patients was ( 34.2 ± 27.1 ) cm3 with the range of 0.4- 153.7 cm3.The 3-year overall survival for V1,V2,V3 and V4 stage were 88.6%,90.0%,91.2% and 74.2%,respectively (x2 =12.83,P =0.005 ).There was no significant difference among V1,V2 and V3in terms of overall survival ( x2 =1.96,P =0.376).The 3-year distant metastasis-free survival and diseasesfree survival or overall survival were decrease in PTV >50 cm3 and PTV≤50 cm3 (77.4%:89.9%,x2 =7.24,P=0.007and 64.5%:85.1%,x2 =13.95,P=0.000 or 74.2%:90.3%,x2 =11.76,P=0.001).Multivariate analysis revealed that PTV was a adverse prognostic factors for overall survival (x2 =0.00,P =2.580).ConclusionOur data showed that the primary tumor volume had significantly impacted on the prognosis of NPC patients treated by intensity modulated radiotherapy.

4.
Chinese Journal of Radiation Oncology ; (6): 506-509, 2011.
Article in Chinese | WPRIM | ID: wpr-422357

ABSTRACT

Objective To measure the set-up errors of patients with head and neck (H&N) cancer during the image guided intensity-modulated radiotherapy (IMRT) treatment and analyze the impact of setup errors on dose distribution ; then to further investigate the necessity of adjustment online for H&N cancer during IMRT treatment.Methods Cone-beam CT (CBCT) scanning of thirty patients with H&N cancer were acquired by once weekly with a total of 6 times during IMRT treatment.The CBCT images and the original planning CT images were matched by the bony structure and worked out the translational errors of the x,y,z axis,as well as rotational errors.The dose distributions were recalculated based on the data of each setup error.The dose of planning target volume (PTV) and organs at risk were calculated in the replanning,and than compared with the original plan by paired t-test.Results The mean value of x,y,z axis translational set-up errors were ( 1.06 ± 0.95 ) mm,( 0.95 ± 0.77 ) mm and ( 1.31 ± 1.07 ) mm,respectively.The rotational error of x,y,z axis were ( 1.04 ±0.791 ),( 1.06 ±0.89) and (0.81 ±0.61 ),respectively.PTV 95% volume dose ( D95 ) and PTV minimal dose of replanning for 6 times set-up were lower than original plan (6526.6 cGy:6630.3 cGy,t =3.98,P =0.000 and 5632.6 cGy:5792.5 cGy,t =- 2.89,P =0.007).Brain stem received 45 Gydose volume ( V45 ) and 1% brain stem volume dose ( D01 )were higher than original plan ( 3.54%:2.75%,t =3.84,P =0.001 and 5129.7 cGy:4919.3 cGy,t =4.36,P =0.000).Conclusions The set-up errors led to the dose of PTV D95 obviously insufficient and significantly increased V45,D01 of the brainstem.So,adjustment online is necessary for H&N cancer during IMRT treatment.

5.
Chinese Journal of Radiation Oncology ; (6): 334-337, 2011.
Article in Chinese | WPRIM | ID: wpr-416605

ABSTRACT

Objective To study the feasibility of dose calculation using kilovoltage X-ray cone-beam CT (KVCBCT) imaging for head-and-neck radiation therapy.Methods 11 patients with nasopharyngeal carcinoma were scanned with KVCBCT to adjust position before treatment, and rescanning images with KVCBCT after correction were input a treatment-planning system.The dose was recalculated by applying the patients′ treatment plans based on planning CT to the KVCBCT images.The dose distributions and dose volume histograms (DVH) of the tumor and critical structures were compared with the original treatment plan.Results The DVH and dose distribution of the plan based on the KVCBCT are compared with that of the planning CT, and they shows a good consistency for the 11 cases.The doses calculated from the planning CT and KVCBCT were compared on the isocenter planes.Using γ analysis with a criterion of 3%/3 mm, 98.0%±1.33% of the points on the isocenter planes in the planning CT and KVCBCT.The difference of the dose to target volume was<1% and to normal structure was<2%.Conclusions This study indicated that CBCT images can be used to make a treatment plan with its individual hounsfield unit-electron density calibration curve.