Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
China Journal of Orthopaedics and Traumatology ; (12): 1012-1016, 2020.
Article in Chinese | WPRIM | ID: wpr-879343

ABSTRACT

OBJECTIVE@#To compare the accuracy of three methods for measuring the length of both lower limbs in hip arthroplasty for femoral neck fracture in the elderly, and to introduce a "shoulder to shoulder" anatomical location marking method for femur.@*METHODS@#From January 2017 to January 2019, 90 elderly patients with femoral neck fracture were treated with hip replacement, including 39 males and 51 females, aged 65 to 96(78.0±7.4) years, 56 cases of total hip and 34 cases of hemi hip. According to garden classification, there were 7 cases of typeⅡ, 63 cases of type Ⅲ and 20 cases of type Ⅳ. The patients were divided into three groups according to different measurement methods:contralateral contrast method (group A) of 19 cases, shuck test method (group B) of 28 cases, and "shoulder to shoulder" anatomical marker localization method (Group C) of 43 cases. The accuracy of the three methods was compared by measuring the length difference of lower limbs in vitro and imaging.@*RESULTS@#All patients completed the operation successfully. After total hip arthroplasty, the length of lower limbs in group A was(12.9±8.6) mm, and that in group B was(10.3±4.4) mm. After hemiarthroplasty, the length of lower limbs in group A was (13.2±7.2) mm, group B was (8.7±3.5) mm, and group C was (6.3±2.8) mm; the measurement results of unequal length of lower limbs after total hip arthroplasty were(12.9±8.1) mm in group A, (9.6±4.0) mm in group B and (6.6±2.6) mm in group C. The results of factorial analysis of variance showed that the differences among the three groups were statistically significant (@*CONCLUSION@#The "shoulder to shoulder" anatomic localization marking method can reduce the length of lower limbs simply, effectively and accurately in the elderly patients with femoral neck fracture hip replacement.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Arthroplasty, Replacement, Hip , Femoral Neck Fractures/surgery , Hemiarthroplasty , Leg Length Inequality/surgery , Lower Extremity , Treatment Outcome
2.
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 278-82, 2015.
Article in English | WPRIM | ID: wpr-637103

ABSTRACT

The factors influencing the incidence of common complications (pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax (13 cases, 27.1%) and pulmonary hemorrhage (14 cases, 20.24%). χ(2) test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases (17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases (60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases (41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases (70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation.

3.
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 278-282, 2015.
Article in English | WPRIM | ID: wpr-331073

ABSTRACT

The factors influencing the incidence of common complications (pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax (13 cases, 27.1%) and pulmonary hemorrhage (14 cases, 20.24%). χ(2) test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases (17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases (60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases (41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases (70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation.


Subject(s)
Female , Humans , Male , Middle Aged , Biopsy, Needle , Methods , Lung Neoplasms , Pathology , Risk Factors , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL