Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Korean Journal of Anesthesiology ; : 606-609, 2019.
Article in English | WPRIM | ID: wpr-917450

ABSTRACT

BACKGROUND@#The laryngeal mask airway (LMAⓇ) Protector™ (Teleflex Medical Co., Ireland) is the latest innovation in the second generation of LMA devices. One distinguishing feature of this device is its integrated, color-coded cuff pressure indicator (Cuff ™ technology) which enables continuous cuff pressure monitoring and allows adjustments when necessary; this ensures patient safety due to better monitoring.CASE: We report a case of postoperative unilateral hypoglossal nerve palsy after uncomplicated use of the LMA Protector. To the best of our knowledge, this could be the second reported case.@*CONCLUSIONS@#This case demonstrates that anesthetists need to routinely measure cuff pressure and that the Cuff Pilot™ technology is not a panacea for potential cranial nerve injury after airway manipulation.

2.
Korean Journal of Anesthesiology ; : 606-609, 2019.
Article in English | WPRIM | ID: wpr-786237

ABSTRACT

BACKGROUND: The laryngeal mask airway (LMAⓇ) Protector™ (Teleflex Medical Co., Ireland) is the latest innovation in the second generation of LMA devices. One distinguishing feature of this device is its integrated, color-coded cuff pressure indicator (Cuff ™ technology) which enables continuous cuff pressure monitoring and allows adjustments when necessary; this ensures patient safety due to better monitoring.CASE: We report a case of postoperative unilateral hypoglossal nerve palsy after uncomplicated use of the LMA Protector. To the best of our knowledge, this could be the second reported case.CONCLUSIONS: This case demonstrates that anesthetists need to routinely measure cuff pressure and that the Cuff Pilot™ technology is not a panacea for potential cranial nerve injury after airway manipulation.


Subject(s)
Cranial Nerve Injuries , Hypoglossal Nerve Diseases , Hypoglossal Nerve , Laryngeal Masks , Patient Safety
3.
Korean Journal of Anesthesiology ; : 289-295, 2018.
Article in English | WPRIM | ID: wpr-716348

ABSTRACT

BACKGROUND: The ideal emergency cricothyroidotomy technique remains a topic of ongoing debate. This study aimed to compare the cannula-to-Melker technique with the scalpel-bougie technique and determine whether yearly training in cricothyroidotomy techniques is sufficient for skill retention. METHODS: We conducted an observational crossover bench study to compare the cannula-to-Melker with the scalpel-bougie technique in a porcine tracheal model. Twenty-eight anesthetists participated. The primary outcome was time taken for device insertion. Secondary outcomes were first-pass success rate, incidence of tracheal trauma, and technique preference. We also compared the data on outcome measures with the data obtained in a similar workshop a year ago. RESULTS: The scalpel-bougie technique was significantly faster than the cannula-to-Melker technique for cricothyroidotomy (median time of 45.2 s vs. 101.3 s; P = 0.001). Both techniques had 100% success rate within two attempts; there were no significant differences in the first-pass success rates and incidence of tracheal wall trauma (P > 0.999 and P = 0.727, respectively) between them. The relative risks of inflicting tracheal wall trauma after a failed cricothyroidotomy attempt were 6.9 (95% CI 1.5–31.1), 2.3 (95% CI 0.3–20.7) and 3.0 (95% CI 0.3–25.9) for the scalpel-bougie, cannula-cricothyroidotomy, and Melker-Seldinger airway, respectively. The insertion time and incidence of tracheal wall trauma were lower when the present data were compared with data from a similar workshop conducted the previous year. CONCLUSIONS: This study supports the use of a scalpel-bougie technique for cricothyroidotomy by anesthetists and advocates a yearly training program for skill retention.


Subject(s)
Airway Management , Education , Emergencies , Incidence , Intubation , Outcome Assessment, Health Care , Trachea , Tracheostomy
4.
Korean Journal of Anesthesiology ; : 580-581, 2017.
Article in English | WPRIM | ID: wpr-217328

ABSTRACT

No abstract available.


Subject(s)
Diagnosis , Pulmonary Embolism
SELECTION OF CITATIONS