Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
China Medical Equipment ; (12): 104-106,107, 2016.
Article in Chinese | WPRIM | ID: wpr-604274

ABSTRACT

Objective:To explore the multi-dimensional method of medical equipment management based on comprehensive index assessment, and improve quality of medical equipment management. Methods: This essay proposed a comprehensive-index-analysis medical equipment management approach within hospital theoretic work and medical equipment management. Equipment management and project application in each clinical department were treated as evaluation criteria which conducted a multi-equality index for medical equipment operation management, using the pattern of quantitative substitute qualitative method.Results: The new method helps to quantize ability of clinical department, equipment utility and management. It refers to scientific equipment management data after procurement, which reflects differences between each department and equipments. Moreover, it helps to prevent blind procurement effectively by ranking department earning capacity.Conclusion: The new method is benefit for equipments’ evaluation and to provide reference for managers in decision-making.

2.
Practical Oncology Journal ; (6): 530-534, 2014.
Article in Chinese | WPRIM | ID: wpr-672397

ABSTRACT

Obj ective In the body of stereotactic radiotherapy ( SBRT ) , using Cone Beam is the matc-hing precision of soft tissue and bone anatomy ,translation between evaluation organization and internal organiza-tion in the rotation of the lung cancer patients with tumor location error ,location correction .Methods Applica-tion varian companies in the United States has the airborne imaging system clinac -ix linear accelerator apparatus treatment of 8 cases of lung cancer patients .By CBCT and SBRT comparison before and after the treatment for each patient and evaluate internal instant translation and rotation of the body of the patients with SBRT postures , tumor location and tumor center of baseline shift score changes .Results Based on the difference between of the anatomy of the bone and soft tissue match position is 3.0 mm(0~8.3 mm).The patient′s tumor location in 3-d median change is 1.4 mm(0~12.2 mm)and 12.2 mm(0~13.2 mm).The median baseline offset between 3 d score is 2.2 mm(0~4.7 mm).The rest of the system error and random error about 1 °.Conclusion In Lung cancer SBRT transformation to improve treatment of lung tumor process , change the position of tumor center is mainly affected by the body′s internal organization instant translation and rotation .

SELECTION OF CITATIONS
SEARCH DETAIL