Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Pharmacology and Therapeutics ; (12): 652-659, 2022.
Article in Chinese | WPRIM | ID: wpr-1014831

ABSTRACT

AIM: To study the distribution of CYP2C9∗3 and VKORC1-1639G>A gene polymorphism in Han population in Anhui province and their influence on the stable dose of warfarin. METHODS: The blood samples of 1 169 patients from 6 tertiary general hospitals in 5 areas of Anhui province from January 2020 to December 2021 were selected, the genotype of CYP2C9∗3 and VKORC1-1639G>A was detected by fluorescent staining in situ hybridization technique. RESULTS: The distribution of CYP2C9∗3 genotypes in 1 169 patients: the frequencies of AA, AC and CC genes were 90.16%, 9.24% and 0.60%, respectively; The distribution of VKORC1 genotype: the frequencies of AA, AG and GG genes were 84.26%, 14.71% and 1.03% respectively; There was no significant difference between the two genotypes in gender, age and regional distribution (P>0.05). The average daily warfarin dose of CYP2C9∗3 AA genotype in 755 patients with stable warfarin dose was (3.02±0.59) mg/d, which was significantly higher than patients with AC genotype and CC genotype; The average daily warfarin dose of patients with VKORC1-1639AA genotype was (2.72±0.40) mg/d, which was significantly lower than that of patients with AG genotype and GG genotype (P<0.05). And the difference was statistically significant (P<0.05); There are significant differences in gender, age and clinical diagnosis between patients with stable dose of warfarin and those without stable dose (P<0.05). CONCLUSION: CYP2C9 and VKORC1 genotypes are associated with the stable dose of warfarin. Clinical anticoagulation therapy guided by CYP2C9 and VKORC1 genotypes can provide guidance for individualized medication of warfarin.

2.
Chinese Journal of Laboratory Medicine ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-584056

ABSTRACT

Objective To study suitability of a series of lyophilized serum with definitive HBV DNA value in fluorescence quantitative COBAS Amplicor HBM kit and a sample with 106 copies/ml HBV DNA was prepared, and sent to various manufactures which would be asked to detect the samples using their own kits. Then a calibration curves from CT values of the series to the corresponding concentrations was compared with that obtained from the external standard-calibration curve with the manufactures series. Results The standard-calibration curve with the series of lyophilized serum showed an excellent correlation (

3.
Chinese Journal of Laboratory Medicine ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-585996

ABSTRACT

Objective To establish a statistics internal quality control method for false-positive in clinical qualitative immunoassays.Methods When the positive rates are normal distribution, the half-Levey-Jennings chart can be used. Based on the positive rates of more than 20 runs routine tests, mean value and standard deviation (SD) were calculated and quality control chart was plotted.The control rules are 1_ +2S for out-of-control.For non-normal distribution data, elementary probability calculation could be used.ResultsThe half-Levey-Jennings chart and elementary probability calculation are suitable for statistics internal quality control method for false-positive in clinical qualitative immunoassays.Conclusion The proposed internal quality control statistics method for false-positive monitoring in clinical qualitative immunoassays is practical and useful.

SELECTION OF CITATIONS
SEARCH DETAIL