Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Microsurgery ; (6)2006.
Article in Chinese | WPRIM | ID: wpr-676125

ABSTRACT

Objective To report the outcome of emergency repair traumatized limbs by vascularized free tissue transplantation.Methods From April 1988 to August 2004,86 patients,58 men and 28 women,had undergone emergency vascularized free tissue transplantation to have their injured limbs repaired in 54 cases and the missing thumbs reconstructed in 32.The patients aged from 5 to 55 (mean 27.9) years. The transplants included latissimus dorsi myocutaneons flap,anterolateral femoral skin flap,medial crural skin flaps,dorsal pedal flaps,medial plantar flap,composite tissue mass of the discarded limbs and big toe skin- nail flap.The operations were performed 1 to 5 days after injuries.Results Postoperative vascular crises occurred in 8 cases and were all followed by exploration with successes in 5 cases while failure in 3.The total survival rate of the transplants was 96.5% (83/86).In this series all the patients were followed up for 1 to 16 years with a mean of 7.5 years only to reveal satisfying functional recovery in all the repaired limbs and an ex- cellent and good rate of 87.5% in the reconstructed thumbs.Conclusion Emergency vascularized free tis- sue transplantation is an effective way to repair a traumatized limb and to reconstruct a traumatically missing thumb.

2.
Journal of Biomedical Engineering ; (6): 840-843, 2005.
Article in Chinese | WPRIM | ID: wpr-238328

ABSTRACT

Resorption and osteolysis of periimplant bones resulting from the wear debris of artificial joint will cause long-term loosening. A new type of rolling knee artificial joint without UHMWPE based on the mechanics of rolling friction is designed for alleviating this problem. Because of low friction force, the resistance of extension and flexion is reduced strikingly and the stress on the interface between prosthesis and bone is reduced evidently. In addition, the bio-toxicity caused by the wear debris of UHMWPE will not occur absolutely. In consequence, the rolling artificial joint can prevent the trend of long-term loosening of the prosthesis efficiently.


Subject(s)
Animals , Dogs , Humans , Arthroplasty, Replacement, Knee , Ceramics , Chemistry , Computer-Aided Design , Knee Prosthesis , Materials Testing , Polyethylenes , Prosthesis Design , Vitallium , Chemistry
3.
Chinese Journal of Microsurgery ; (6)2000.
Article in Chinese | WPRIM | ID: wpr-537998

ABSTRACT

Objective To report the technique and outcome of combined transplantation of bilateral vascularized fibulas to repair the segmental femoral defect Method In the period from October 1984 to May 1992, bilateral vascularized fibula transfer was done to treat femoral defects in 9 cases, in which there were 5 cases of bone tumor, 3 cases of pathological fractures following chronic osteomyelitis and 1 case of posttraumatic bone defect The length of the transferred fibulas ranged from 12 cm to 22 cm and averaged 16.25 cm Result Except 1 case in which thigh amputation was done 6 months after operation because of local recurrence of the chondrosarcoma, all the transferred fibulas united solidly with the host bones 3-6 months after operation The repaired limbs started weight-bearing at the third to seventh postoperative month Conclusion To repair a femoral defect over 10 cm in length, combined transfer of bilateral vascularized fibulas is the treatment of choice with short therapeutic process and good results.

SELECTION OF CITATIONS
SEARCH DETAIL