Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Braz. j. microbiol ; 49(1): 128-137, Jan.-Mar. 2018. tab, graf
Article in English | LILACS | ID: biblio-889212

ABSTRACT

ABSTRACT We developed a loop-mediated isothermal amplification (LAMP) assay for the detection of Y. pestis by targeting the 3a sequence on chromosome. All 11 species of the genus Yersinia were used to evaluate the specificity of LAMP and PCR, demonstrating that the primers had a high level of specificity. The sensitivity of LAMP or PCR was 2.3 or 23 CFU for pure culture, whereas 2.3 × 104 or 2.3 × 106 CFU for simulated spleen and lung samples. For simulated liver samples, the sensitivity of LAMP was 2.3 × 106 CFU, but PCR was negative at the level of 2.3 × 107 CFU. After simulated spleen and lung samples were treated with magnetic beads, the sensitivity of LAMP or PCR was 2.3 × 103 or 2.3 × 106 CFU, whereas 2.3 × 105 or 2.3 × 107 CFU for magnetic bead-treated liver samples. These results indicated that some components in the tissues could inhibit LAMP and PCR, and liver tissue samples had a stronger inhibition to LAMP and PCR than spleen and lung tissue samples. LAMP has a higher sensitivity than PCR, and magnetic bead capture of DNAs could remarkably increase the sensitivity of LAMP. LAMP is a simple, rapid and sensitive assay suitable for application in the field or poverty areas.


Subject(s)
Humans , Plague/microbiology , DNA, Bacterial/genetics , Nucleic Acid Amplification Techniques/methods , Magnetics/methods , Yersinia pestis/isolation & purification , Yersinia pestis/classification , Yersinia pestis/genetics , DNA, Bacterial/isolation & purification , DNA, Bacterial/chemistry , Polymerase Chain Reaction , Sensitivity and Specificity , Immunomagnetic Separation , DNA Primers/genetics , Nucleic Acid Amplification Techniques/instrumentation , Magnetics/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL