Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
International Journal of Biomedical Engineering ; (6): 201-204, 2012.
Article in Chinese | WPRIM | ID: wpr-420319

ABSTRACT

Objective To design a wireless transmission solution of multi-parameter vital signs signal which can be applied in psychological status assessment.Methods C8051F350 SOC was used to define data frame structure,on application level,including channel number,control words,data and so on,which put all nodes data into the upper computer cache area by channel in an orderly way.A transfer rate of five seconds on a grid,each grid at least 48 groups of data was chosen in buffer,which could not only match the dynamic PC image display,but also to achieve the stability of the channel signal acquisition and orderly transfer.Results After operating test,with the communication distance within 10~15 m,the dynamical display of the upper computer showed a smooth curve data,which met the system design requirement.After optimization of the data frame,the transmission power could be reduced to 1/12 of that of normal mode.The whole system with three advantages of small size,low power and easy to carry.Conclusion Multi-parameter wireless acquisition system described in this paper eliminates the data line connected to the subjects,which does not affect their normal activities and is conducive to the real response of subjects' mental state,and provides a reliable means of detection for psychological assessment.

2.
Chinese Journal of Practical Internal Medicine ; (12)2002.
Article in Chinese | WPRIM | ID: wpr-566038

ABSTRACT

Objective In order to investigate the comlex course of electricity and mechanism of erosive gastritis(EG) and its relative factors,and to extract gastric motility feature indexes.Methods 30 volunteers of erosive gastritis were selected.The signal processing device was designed by Chongqing University of Posts and Telecommunications.By the means of spectrum analysis technic,the signals could be classified according to the dominant power and dominant frequency.Some indexes such as frequency of EGG and IGM,signal power spectrum and dynamic spectrum,the rates of rhythm and power for the normal EGG and IGM and so on could also be calculated.Results The power ratio in 2~4 cpm was 59.2?4.4,the frequency ratio was 70.4?25.5,the frequency instability coefficient was 0.182?0.059,and the power instability coefficient was 1.576?0.481.The parameters changed signifcantly between health adult and patient(P0.05).Conclusion The results of the experiments show that the method based on the synchronous measurement of EGG and IGM can provide a non-invasive way to investigate and evaluate erosive gastritis corresponding to gastrointestinal physiology and pathology conditions.

SELECTION OF CITATIONS
SEARCH DETAIL