Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Regional Anatomy and Operative Surgery ; (6): 841-844, 2017.
Article in Chinese | WPRIM | ID: wpr-702197

ABSTRACT

Objective To explore the clinical effects of Ilizarov technology combined with closed minimally invasive osteotomy and slow tissue distraction in the treatment of complex crus malformations.Methods From June 2006 to February 2016,83 cases suffering complex crus malformations in our department were treated by Ilizarov technique combined with closed minimally invasive osteotomy and slow tissue distraction.Of whom,39 cases were traumatic bone defect,36 cases were bone osteomyelitis,8 cases were congenital pseudarthrosis of tibia.Bone defect ranged from 6 to 11 cm,with an average of 8 cm.All cases were conducted by segmental resection of bone lesions combined with closed minimally invasive osteotomy and Ilizarov technique.The functional evaluation was carried out according to the Paley evaluation criterion.Bone healing time,duration of external fixation,postoperative limb lengthening and limb function recovery were recorded.Results Eighty-three patients were followed up for 8 to 36 months,with an average of 16 months.All patients' crus malformations were completely corrected.The external fixation time was from 6 to 18 months,with an average of 10.3 months;the length of the limb lengthening was from 4.5 to 9 cm,with an average of 6.3 cm;and bone healing time was from 6 to 15 months,with an average of 9.8 months.According to the Paley evaluation criterion,53 cases were excellent,24 cases were good,6 cases were general.Conclusion Ilizarov technology combined with closed minimally invasive osteotomy and slow tissue distraction a reliable method to correct the complex deformity of the tibia and fibula.

2.
China Journal of Orthopaedics and Traumatology ; (12): 476-481, 2015.
Article in Chinese | WPRIM | ID: wpr-241012

ABSTRACT

Spinal biomechanics, especially the range of spine motion,has close connection with spinal surgery. The change of the range of motion (ROM) is an important indicator of diseases and injuries of spine, and the essential evaluating standards of effect of surgeries and therapies to spine. The analysis of ROM can be dated to the time of the invention of X-ray and even that before it. With the development of science and technology as well as the optimization of various types of calculation methods, diverse measuring methods have emerged, from imaging methods to non-imaging methods, from two-dimensional to three-dimensional, from measuring directly on the X-ray films to calculating automatically by computer. Analysis of ROM has made great progress, but there are some older methods cannot meet the needs of the times and disappear, some classical methods such as X-ray still have vitality. Combining different methods, three dimensions and more vivo spine research are the trend of analysis of ROM. And more and more researchers began to focus on vivo spine research. In this paper, the advantages and disadvantages of the methods utilized recently are presented through viewing recent literatures, providing reference and help for the movement analysis of spine.


Subject(s)
Animals , Humans , Imaging, Three-Dimensional , Methods , Radiography , Spine , Diagnostic Imaging
SELECTION OF CITATIONS
SEARCH DETAIL