1.
Journal of Southern Medical University ; (12): 192-200, 2019.
Article in Chinese | WPRIM | ID: wpr-772099

ABSTRACT

OBJECTIVE@#To develop a digital breast tomosynthesis (DBT) imaging system with optimizes imaging chain.@*METHODS@#Based on 3D tomography and DBT imaging scanning, we analyzed the methods for projection data correction, geometric correction, projection enhancement, filter modulation, and image reconstruction, and established a hardware testing platform. In the experiment, the standard ACR phantom and high-resolution phantom were used to evaluate the system stability and noise level. The patient projection data of commercial equipment was used to test the effect of the imaging algorithm.@*RESULTS@#In the high-resolution phantom study, the line pairs were clear without confusing artifacts in the images reconstructed with the geometric correction parameters. In ACR phantom study, the calcified foci, cysts, and fibrous structures were more clearly defined in the reconstructed images after filtering and modulation. The patient data study showed a high contrast between tissues, and the lesions were more clearly displayed in the reconstructed image.@*CONCLUSIONS@#This DBT imaging system can be used for mammary tomography with an image quality comparable to that of commercial DBT systems to facilitate imaging diagnosis of breast diseases.


Subject(s)
Female , Humans , Algorithms , Artifacts , Breast , Diagnostic Imaging , Mammography , Methods , Phantoms, Imaging , Radiographic Image Enhancement , Methods
2.
Journal of Southern Medical University ; (12): 1213-1220, 2019.
Article in Chinese | WPRIM | ID: wpr-773475

ABSTRACT

OBJECTIVE@#We propose a sparse-view helical CT iterative reconstruction algorithm based on projection of convex set tensor total generalized variation minimization (TTGV-POCS) to reduce the X-ray dose of helical CT scanning.@*METHODS@#The three-dimensional volume data of helical CT reconstruction was viewed as the third-order tensor. The tensor generalized total variation (TTGV) was used to describe the structural sparsity of the three-dimensional image. The POCS iterative reconstruction framework was adopted to achieve a robust result of sparse-view helical CT reconstruction. The TTGV-POCS algorithm fully used the structural sparsity of first-order and second-order derivation and the correlation between the slices of helical CT image data to effectively suppress artifacts and noise in the image of sparse-view reconstruction and better preserve image edge information.@*RESULTS@#The experimental results of XCAT phantom and patient scan data showed that the TTGVPOCS algorithm had better performance in reducing noise, removing artifacts and maintaining edges than the existing reconstruction algorithms. Comparison of the sparse-view reconstruction results of XCAT phantom data with 144 exposure views showed that the TTGV-POCS algorithm proposed herein increased the PSNR quantitative index by 9.17%-15.24% compared with the experimental comparison algorithm; the FSIM quantitative index was increased by 1.27%-9.30%.@*CONCLUSIONS@#The TTGV-POCS algorithm can effectively improve the image quality of helical CT sparse-view reconstruction and reduce the radiation dose of helical CT examination to improve the clinical imaging diagnosis.

3.
Journal of Southern Medical University ; (12): 1331-1337, 2018.
Article in Chinese | WPRIM | ID: wpr-771472

ABSTRACT

OBJECTIVE@#To establish a cone beam computed tomography (ECBCT) system for high-resolution imaging of the extremities.@*METHODS@#Based on three-dimensional X-Ray CT imaging and high-resolution flat plate detector technique, we constructed a physical model and a geometric model for ECBCT imaging, optimized the geometric calibration and image reconstruction methods, and established the scanner system. In the experiments, the pencil vase phantom, image quality (IQ) phantom and a swine feet were scanned using this imaging system to evaluate its effectiveness and stability.@*RESULTS@#On the reconstructed image of the pencil vase phantom, the edges were well preserved with geometric calibrated parameters and no aliasing artifacts were observed. The reconstructed images of the IQ phantom showed a uniform distribution of the CT number, and the noise power spectra were stable in multiple scanning under the same condition. The reconstructed images of the swine feet had clearly displayed the bones with a good resolution.@*CONCLUSIONS@#The ECBCT system can be used for highresolution imaging of the extremities to provide important imaging information to assist in the diagnosis of bone diseases.


Subject(s)
Animals , Algorithms , Artifacts , Calibration , Cone-Beam Computed Tomography , Methods , Equipment Design , Extremities , Diagnostic Imaging , Image Processing, Computer-Assisted , Methods , Phantoms, Imaging , Radiographic Image Enhancement , Methods , Swine