Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. bras. cir. cardiovasc ; 38(4): e20220355, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1449561

ABSTRACT

ABSTRACT Introduction: The European System for Cardiac Operative Risk Evaluation (EuroSCORE) II and the Society of Thoracic Surgeons (STS) are validated scoring systems for short-term risk estimation after coronary artery bypass grafting (CABG). The Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) risk score is originally aimed to estimate mortality in heart failure patients; however, it has showed a similar power to predict mortality after heart valve surgery. In this study, we sought to evaluate whether MAGGIC score may predict short and long-term mortality after CABG and to compare its power with EuroSCORE II and STS scoring systems. Methods: Patients who underwent CABG due to chronic coronary syndrome at our institution were included in this retrospective study. Follow-up data were used to define the predictive ability of MAGGIC and to compare it with STS and EuroSCORE-II for early, one-year, and up to 10-year mortality. Results: MAGGIC, STS, and EuroSCORE-II scores had good prognostic power, moreover MAGGIC was better for predicting 30-day (area under the curve [AUC]: 0.903; 95% confidence interval [CI]: 0.871-0.935), one-year (AUC: 0.931; 95% CI: 0.907-0.955), and 10-year (AUC: 0.923; 95% CI: 0.893-0.954) mortality. MAGGIC was found to be an independent predictor to sustain statistically significant association with mortality in follow-up. Conclusion: MAGGIC scoring system had a good predictive accuracy for early and long-term mortality in patients undergoing CABG when compared to EuroSCORE-II and STS scores. It requires limited variables for calculation and still yields better prognostic power in determining 30-day, one-year, and up to 10-year mortality.

2.
Rev. Assoc. Med. Bras. (1992) ; 67(9): 1311-1316, Sept. 2021. tab
Article in English | LILACS | ID: biblio-1351458

ABSTRACT

SUMMARY INTRODUCTION: According to recent studies, the rate of atrioventricular block requiring permanent pacing in patients following transcatheter aortic valve implantation varied between 5.7% and 42.5%. Fragmented QRS is a useful marker of myocardial scar and can predict adverse cardiac events. In this study, we examined association between f ragmented QRS and postprocedural rhythm disturbances and the need for permanent pacing in patients who underwent transcatheter aortic valve implantation. OBJECTIVE: In this study, we examined association between fragmented QRS and postprocedural rhythm disturbances and the need for permanent pacing in patients who underwent transcatheter aortic valve implantation' sentence is enough for it. METHODS: We retrospectively analyzed standard 12-lead electrocardiographic recordings of 124 consecutive patients in whom a CoreValve prosthesis was implanted. We examined 12-lead electrocardiogram before and after procedure along with one- and six-month follow-up. We documented QRS fragmentation and postprocedural rhythm disturbances. RESULTS: There was a significant increase in the frequency of left bundle branch block, (21.1 versus 0%, p<0.05) and the incidence of atrioventricular blocks requiring permanent pacing (21.1 versus 0%, p<0.05) following transcatheter aortic valve implantation in patients whose preprocedural electrocardiogram recordings revealed fragmented QRS compared to those without fragmented QRS. Based our collected data, the presence of QRS fragmentation in anterior derivations was the only independent factor associated with postprocedural rhythm disturbances (B-value 0.217; OR 0.805; 95%CI 0.136-4.78; p=0.004). CONCLUSION: Our data showed an increased risk for the development of new-onset left bundle branch block and atrioventricular blocks following transcatheter aortic valve implantation in patients whose baseline electrocardiogram recordings demonstrated QRS fragmentation.


Subject(s)
Humans , Aortic Valve Stenosis/surgery , Pacemaker, Artificial , Heart Valve Prosthesis/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Cardiac Pacing, Artificial , Retrospective Studies , Risk Factors , Treatment Outcome , Electrocardiography
SELECTION OF CITATIONS
SEARCH DETAIL